Cisco ASA 5545-X ASA5545-2SSD120-K9 数据表

产品代码
ASA5545-2SSD120-K9
下载
页码 10
 
 
© 2013-2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 4 of 10 
Feature 
Cisco ASA 5512-X, 
Security Plus 
Cisco ASA  
5515-X 
Cisco ASA 
5525-X 
Cisco ASA 
5545-X 
Cisco ASA 
5555-X 
Relative humidity 
10 to 90 percent 
noncondensing 
10 to 90 percent 
noncondensing 
90 percent 
90 percent 
90 percent 
Altitude 
Designed and tested 
for 0 to 15,000 ft 
(4572 m) 
Designed and tested 
for 0 to 15,000 ft 
(4572 m) 
Designed and tested 
for 0 to 10,000 ft 
(3050 m) 
Designed and tested 
for 0 to 10,000 ft 
(3050 m) 
Designed and tested 
for 0 to 10,000 ft 
(3050 m) 
Shock 
70 G, 4.22 m/sec 
70 G, 4.22 m/sec 
50 G, 2 m/sec 
50 G, 2 m/sec 
50 G, 2 m/sec 
Vibration 
0.41 Grms2 (3 to 500 
Hz) random input 
0.41 Grms2 (3 to 500 
Hz) random input 
0.41 Grms2 (3 to 500 
Hz) random input  
0.41 Grms2 (3 to 500 
Hz) random input 
0.41 Grms2 (3 to 500 
Hz) random input 
Acoustic noise 
64.2 A-weighted 
decibels (dBA) max 
64.2 dBA max 
64.2 dBA max 
67.9 dBA max 
67.9 dBA max 
Nonoperating  
Temperature 
-13 to 158ºF (-25 to 
70ºC) 
-13 to 158ºF (-25 to 
70ºC) 
-13 to 158°F (-25 to 
70°C) 
-13 to 158°F (-25 to 
70°C) 
-13 to 158°F (-25 to 
70°C) 
Relative humidity 
10 to 90 percent 
noncondensing 
10 to 90 percent 
noncondensing 
10 to 90 percent 
10 to 90 percent 
10 to 90 percent 
Altitude 
Designed and tested 
for 0 to 15,000 ft 
(4570 m) 
Designed and tested 
for 0 to 15,000 ft 
(4570 m) 
Designed and tested 
for 0 to 15,000 ft (457 
2m) 
Designed and tested 
for 0 to 15,000 ft 
(4572 m) 
Designed and tested 
for 0 to 15,000 ft 
(4572 m) 
Shock 
70G, 4.22 m/sec 
70G, 4.22 m/sec 
70G, 4.22 m/sec 
70G,4.22 m/sec 
70G, 4.22 m/sec 
Vibration 
1.12 Grms2 (3 to 500 
Hz) random input 
1.12 Grms2 (3 to 500 
Hz) random input 
1.12 Grms2 (3 to 500 
Hz) random input  
1.12 Grms2 (3 to 500 
Hz) random input 
1.12 Grms2 (3 to 500 
Hz) random input 
Power 
Input (per power supply) 
AC range line voltage 
100 to 240 volts 
alternating current 
(VAC) 
100 to 240 VAC 
100 to 240 VAC 
100 to 240 VAC 
100 to 240 VAC 
AC normal line 
voltage 
100 to 240 VAC 
100 to 240 VAC 
100 to 240 VAC 
100 to 240 VAC 
100 to 240 VAC 
AC current 
4.85A 
4.85A 
4.85A 
5A, 100 to 120V 
2.5A, 200 to 240V 
5A, 100 to 120V 
2.5A, 200 to 240V 
AC frequency 
50/60 Hz  
50/60 Hz 
50/60 Hz 
50/60 Hz 
50/60 Hz 
Dual-power supplies 
None 
None 
None 
Yes 
Yes 
DC domestic line 
voltage 
-40.5 to 56 volts direct 
current (VDC) (-48 
VDC nominal) 
-40.5 to 56 VDC (-48 
VDC nominal) 
-40.5 to 56 VDC (-48 
VDC nominal) 
-40.5 to 56 VDC  
(-48 VDC nominal) 
-40.5 to 56 VDC  
(-48 VDC nominal) 
DC international line 
voltage 
-55 to -72 VDC 
(-60 VDC nominal) 
-55 to -72 VDC 
(-60 VDC nominal) 
-55 to -72 VDC  
(-60 VDC nominal) 
-55 to -72 VDC  
(-60 VDC nominal) 
-55 to -72 VDC  
(-60 VDC nominal) 
DC current 
15A (maximum input) 
15A (maximum input) 
15A (maximum input) 
15A (maximum input) 
15A (maximum input) 
Output 
Steady state 
51W 
65W 
75W 
86W 
90W 
Maximum peak 
56W 
70W 
108W 
125W 
134W 
Maximum heat 
dissipation 
192 British thermal 
units (Btu)/hr 
239 Btu/hr 
369 Btu/hr 
427 Btu/hr 
458 Btu/hr 
Form factor 
1 rack unit (RU), 19-
in. rack-mountable 
1RU, 19-in. rack-
mountable 
1RU, 19-in. rack-
mountable 
1RU, 19-in. rack-
mountable 
1RU, 19-in. rack-
mountable 
Dimensions  
(H x W x D) 
1.67 x 16.7 x 15.6 In 
(4.24 x 42.9 x 39.5 
cm) 
1.67 x 16.7 x 15.6 In  
(4.24 x 42.9 x 39.5 
cm) 
1.75 x 17.5 x 14.25 in.  
(4.45 x 20.04 x 36.20 
cm) 
1.67 x 16.7 x 19.1 in.  
(4.24 x 42.9 x 48.4 
cm) 
1.67 x 16.7 x 19.1 in.  
(4.24 x 42.9 x 48.4 
cm)