Chapter 2 — Replacing Parts 
Replacing the IT4000 Imager 
To replace the IT4000 imager, you need the following tools and parts: 
•  T10 Torx screwdriver 
•  Small Phillips screwdriver 
•  IT4000 imager assembly (P/N 073416S-001) 
•  Phillips 4-20 x .250 thread-form screw (P/N 525023) 
To replace the IT4000 imager 
 
Open the CK30. For help, see “Opening the CK30” on page 9. 
From the bottom cover, remove the three Phillips screws that attach 
the IT4000 imager assembly. 
Lift the imager assembly away from the bottom cover. 
 
 
Screw
(3 places)
IT4000
imager
assembly
 
Insert the new imager assembly and attach it with the three Phillips 
screws removed in Step 2. 
Close the CK30. For help, see “Closing the CK30” on page 27. 
Replacing the Tethered Scanner 
To replace the tethered scanner, you need the following tools: 
•  T10 Torx screwdriver 
•  Small Phillips screwdriver 
•  Small straight-slot screwdriver 