Intermec 073296-001 用户手册

下载
页码 113
Chapter 2 — Replacing Parts 
 
 
 
Tethered
scanner
door
 
Insert a new tethered scanner door and snap it in place. 
Insert a new tethered scan flex assembly into the mounting bracket and 
attach it with the two screws removed in Step 4. 
Insert the tethered scan flex assembly into the bottom cover and attach 
it with the four screws removed in Step 2. 
Close the CK30. For help, see the next procedure, “Closing the CK30.” 
Closing the CK30 
To close the CK30, you need the following tools: 
•  T10 Torx screwdriver 
•  Small Phillips screwdriver 
•  Phillips 2-56 x .312 screw (P/N 590371-001) 
•  Torx 4-40 x .25 machine screw (P/N 590870-001) 
•  Torx 4-20 x .625 self-tapping screw (P/N 590872-001) 
•  Phillips flathead 4-40 x .875 screw (P/N 591882-001) 
To close the computer 
 
Connect the trigger reed switch cable to J4 on the main PCB. 
Connect the scanner or imager flex cable to the main PCB. Make sure you 
completely insert the scan flex cable up to the white alignment mark. 
Carefully close the top and bottom covers. Make sure that the cables are not 
pinched between the two covers. 
CK30 Handheld Computer Service Manual 
27