Product Overview 
Intel
®
 Entry Server Chassis SC5299-E TPS 
  
Revision 
3.1 
Intel order number D37594-005 
This specification details the key features of the product. Reference documents listed at the 
back of this document provide additional product specification details for the server boards, 
backplanes, and power supplies validated for use with this chassis. Check the compatibility, 
section on the support website for more details: 
http://www.intel.com/p/en_US/support/highlights/server/sc5299-e
The following table summarizes the features for all chassis combinations: 
Table 1. Intel
®
 Entry Server Chassis SC5299-E UP, DP, BRP, and WS Features
 
Configuration 
SC5299UP 
SC5299DP 
SC5299BRP 
SC5299WS 
Intel
®
 Server 
Board Support 
Intel
®
 Server Board 
S3200SHV 
Intel
®
 Server Board 
S3210SHLC 
Intel
®
 Server Board 
S3210SHLX 
Intel
®
 Server Board  
S3430GPV 
Intel
®
Server Board 
S5000VSA 
Intel
®
 Server Board 
S5000PSL 
Intel
®
 Server Board 
S5000XSL 
Intel
®
 Server Board 
S3420GPLC 
Intel
®
 Server Board 
S3420GPLX 
Intel
®
 Server Board 
S5000VSA 
Intel
®
 Server Board 
S5000PSL 
Intel
®
 Server Board 
S5000XSL 
Intel
®
 Server Board 
S3420GPLC 
Intel
®
 Server Board 
S3420GPLX 
Intel
®
 Server Board 
S5000XVN 
Power Delivery 
420-W PFC Intel 
validated PSU with 
integrated cooling fan. 
550-W PFC Intel 
validated PSU with 
integrated cooling fan. 
650-W PFC Intel 
validated PSU with 
integrated cooling fan. 
One additional 650-W 
PSU can be added for 
redundancy. 
670-W PFC Intel 
validated PSU with 
integrated cooling fan. 
System Cooling 
One tool-less, 120-mm chassis fan. 
One tool-less, 120-mm 
chassis fan. One tool-
less 92-mm drive bay 
fan. 
Peripheral Bays 
Two tool-less, multi-mount 5.25-in peripheral bays. One standard 3.5-in removable media peripheral 
bay. 
Drive Bays 
Includes one tool-less fixed drive bay. Supports 
up to four hard drives. 
Optional hot-swap tool-less drive bay is available. 
Includes one tool-less 
fixed drive bay for up to 
six fixed drives. 
Optional hot-swap tool-
less six-drive bay is 
available. 
PCI Slots 
7 slots and support for 6 full-length with tail card guide 
Form Factor 
5.2U tower, convertible to 6U rack mount 
Front Panel 
LEDs for NIC1, NIC2, HDD activity, power status, and system fault status. 
Switches for power, NMI, and reset. 
Integrated temperature sensor for fan speed management. 
External front 
Two USB ports