Lenovo 3500 M4 7383G9G 用户手册
产品代码
7383G9G
IBM System x3500 M4
35
Power supplies and redundant cooling
The server supports up to two redundant power supplies. Standard models come with one or two power
supplies (model dependent). The server also comes standard with either two (for models with one
processor installed) or three (for models with two processors installed) simple swap cooling fans. Optional
upgrade is available to provide N+N cooling redundancy. The following table lists the power supplies and
redundant cooling upgrade option.
supplies (model dependent). The server also comes standard with either two (for models with one
processor installed) or three (for models with two processors installed) simple swap cooling fans. Optional
upgrade is available to provide N+N cooling redundancy. The following table lists the power supplies and
redundant cooling upgrade option.
Table 16. Power supplies
Part
number
number
Feature
code
code
Description
Maximum
supported
supported
Standard models
where used
where used
94Y5975
A22M
IBM System x 550W High Efficiency Platinum AC
Power Supply
Power Supply
2
-
94Y5974
A1G8
IBM System x 750W High Efficiency Platinum AC
Power Supply
Power Supply
2
A2x, B2x, C2x, C4x,
D2x, F2x
D2x, F2x
94Y5973
A1G7
IBM System x 900W High Efficiency Platinum AC
Power Supply
Power Supply
2
G2x, H2x, J2x
81Y7007
A1G2
Redundant Cooling Upgrade Kit
1
-
An AC power supply ships standard without a line cord, it must be purchased separately. The redundant
cooling kit contains three simple swap fans. Certain rules apply to the selection of power supply, these
rules are listed in Table 17. Table 17 uses the following conventions:
cooling kit contains three simple swap fans. Certain rules apply to the selection of power supply, these
rules are listed in Table 17. Table 17 uses the following conventions:
A grey cell means that the server can be filled with drives, GPUs, processors and DIMMs up to the
maximum number according to server specifications.
A yellow cell means that the maximum number of drives, GPUs, processors or DIMMs that the server
can hold is fewer than the total number listed in server specifications.
Table 17. Configuration rules based on power supply used (PSU = power supply unit, NS = no support)
Max. drive qty
Max. DIMM qty supported
Power
supply
supply
PSU
qty
qty
PSU
red.*
red.*
2.5"
3.5"
Intermixing
2.5" + 3.5"
2.5" + 3.5"
Max.
GPU
qty
GPU
qty
CPU
support
support
UDIMM
RDIMM
LRDIMM
1
No
8
8
No support
NS
Max. 95 W
16
16 SR or DR
(NS for QR)
(NS for QR)
NS
550 W
2
Yes
8
8
No support
NS
Max. 95 W
16
16 SR or DR
(NS for QR)
(NS for QR)
NS
1
No
16
8
8 + 8 drives
NS
All (135 W) 16
24
16
750 W
2
Yes
16
8
8 + 8 drives
NS
All (135 W) 16
24
16
1
No
32
8
8 + 8 drives
NS
All (135 W) 16
24
16
1
No
8
8
No support
1 GPU
All (135 W) 16
24
16
1
No
16
8
8 + 8 drives
NS
All (135 W) 16
24
24
2
Yes
32
8
8 + 8 drives
NS
All (135 W) 16
24
16
2
Yes
8
8
No support
1 GPU
All (135 W) 16
24
16
2
Yes
16
8
8 + 8 drives
NS
All (135 W) 16
24
24
900 W
2
No
32
8
8 + 8 drives
2 GPUs
All (135 W) 16
24
24
* PSU redundancy