Bosch DS9371 用户手册

下载
页码 3
Certifications and approvals
Region
Certification
Europe
CE
89/336/EEC, EN55022: 1998 +A1:
2000 +A2: 2003, EN50130-4: 1996
+A1: 1998 +A2: 2003, EN61000-4-2:
1995 +A1: 1998 +A2: 2001,
EN61000-4-3: 2002 +A1: 2003,
EN61000-4-4: 1995 +A1: 2000 +A2:
2001, EN61000-4-5: 1995 +A1: 2001,
EN61000-4-6: 1996 +A1: 2001 +A2:
2001, EN61000-4-11: 1994 +A1:
2001, EN60950-1: 2001 +A11: 2004,
EN 300 440-2 V1.1.1: 2001-09, EN
300 489 Parts-1 and -3 V1.2.1:
2000-08
USA
UL
ANSR: Intrusion Detection Units
(UL639), ANSR7: Intrusion Detection
Units Certified for Canada (cULus)
FCC
ESV9370
Brazil
ANATEL
Certificado Anatel 0871-03-1855
[DS9370 & DS9371]
Installation/configuration notes
10.5 m
0 m
0 ft
35 ft
10.5 m
35 ft
Top View
10.5 m
0 m
0 ft
35 ft
2.5 m
8 ft
0 m
0 ft
Side View
Coverage Information
The coverage pattern consists of 21 barriers grouped
into three groups of seven barriers each. Each barrier
is 10 m (35 ft) long and 1.5 m (5 ft) wide at 10 m (35
ft). Each group has vertical adjustments for
customized coverage.
Mounting Considerations
The mounting height range is from 2.4 m to 7.6 m (8 ft
to 25 ft). The recommended mounting height range is
from 3.7 m to 7.6 m (12 ft to 25 ft). The coverage area
can be set between 9.1 m and 21.3 m (30 ft and 70 ft).
If mounted at 2.4 m (8 ft) high, the coverage area can
be set between 6.1 m and 12.2 m (20 ft and 40 ft). If
mounted at 3 m (10 ft) high, the coverage area can be
set between 6.1 m and 15.2 m (20 ft and 50 ft).
These detectors can be mounted directly on the
ceiling or on a standard 9 cm (3.5 in.) rectangular
electrical box.
The maximum range of the detector depends on the
mounting height and the vertical adjustment of the PIR
coverage pattern. In areas where part of the area
needs a targeted coverage, the optical modules can be
adjusted for the correct coverage.
A masking kit containing two 120° and two 90° masks
is included to allow masking unwanted areas. Apply
the masks to the outside of the detector. With the
supplied masks, you can mask 90°, 120°, 180°, 210°,
240°, or 330°.
Power Considerations
• Power Limits: Input power must be provided by an
Approved Limited Power Source. All outputs must be
connected to safety extra-low voltage (SELV) circuits
only.
• Standby Power: This detector has no internal standby
battery. For UL Listed product installations, four
hours (116 mAh in standby; 156 mAh in alarm) of
standby power must be supplied by the control unit
or by a UL Listed burglary power supply.
Technical specifications
Enclosure Design
Design:
Modular chassis and hinged mounting base
design provide easy access to setup switches
and wiring.
Dimensions:
8.9 cm x 17.8 cm
(3.5 in. x 7 in.)
Material:
High impact ABS plastic enclosure
Environmental Considerations
Operating
Temperature:
-40°C to +49°C (-40°F to +120°F)
For UL Certificated installations, 0°C to +49°C
(+32°F to +120°F)
Radio
Frequency
Interference
(RFI) Immunity:
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m.
2 | DS9371 Panoramic TriTech Detector