4.4   Maintenance, Diagnostic Commands 
 
C141-C008 
4-193 
4.4.4  READ BUFFER (3C)  
 
 Bit 
Byte 
7 6 5 4 3 2 1 0 
0 X‘3C’ 
1 0 
Mode 
X‘00’ (Buffer ID) 
Buffer Offset  (MSB) 
4 Buffer 
Offset 
Buffer Offset  (LSB) 
Transfer Byte Length  (MSB) 
Transfer Byte Length 
Transfer Byte Length  (LSB) 
0 0 0 0 0 0 0 0 
 
This command is used in combination with the WRITE BUFFER command to 
diagnose the normalcy of the IDD’s data buffer memory and the FC interface. 
The IDD have a 6,733 K (6,895,200) byte size data buffer.  In this command, each 
data byte position in the data buffer must be specified in 4-byte units using buffer 
addresses within the range X'000000' to X'693660'. 
The functions of this command and the contents of the data transferred to the 
INIT are specified by the “Mode” field in the CDB and one of the transfer modes 
shown in Table 4.126 can be selected. 
Table 4.126  READ BUFFER transfer mode 
“Mode” 
Bit 3 2 1 0 
Transfer 
Mode 
 
Header + Data, without Address Specification 
 
Header + Data, with Address Specification 
 
Data Only, with Address Specification 
 
0 0 1 1 
Buffer 
Descriptor 
 
1 0 1 0 
Echo 
buffer 
 
1 0 1 1 
Echo 
buffer 
descriptor