SPECIFICATION
MODEL
ELN-60-12
ELN-60-9
ELN-60-15
ELN-60-24
ELN-60-27
ELN-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.7
CURRENT ADJ. RANGE
Note.7
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
12V
6 ~ 12V
5A
9V
15V
7.5 ~ 15V
24V
12 ~ 24V
48V
24 ~ 48V
5A
2.5A
2.3A
27V
13.5 ~ 27V
1.3A
0 ~ 5A
0 ~ 5A
0 ~ 4A
4A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.3A
60W
45W
60W
60W
62.1W
62.5W
120mVp-p
10.8 ~ 13.2V
120mVp-p
150mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
200mVp-p
24.3 ~ 29.7V
250mVp-p
43.2 ~ 52.8V
¡Ó5.0%
-25% ~ 3%. Can be adjusted by internal potentiometer SVR2
¡Ó1.0%
¡Ó2.0%
500ms, 30ms / 230VAC 15
at full load
00ms, 30ms / 115VAC
90 ~ 264VAC
127 ~ 370VDC
47 ~ 63Hz
82%
85%
86%
87%
87%
88%
13.8 ~ 16V
11 ~ 13.5V
17.5 ~ 21V
28 ~ 32V
31 ~ 37V
54 ~ 60V
1.2A/115VAC
0.7A/230VAC
0.25mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-20 ~ +60
¢J (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
¢J
¡Ó
¢J
¢J
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
603K hrs min.
MIL-HDBK-217F (25
)
¢J
181*61.5*35mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
9. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
¢J
0.4Kg; 24pcs/11Kg/0.75CUFT
60W Single Output Class 2 Switching Power Supply
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.9)
100% full load burn-in test
Low cost, high reliability
2 years warranty
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¢º
Class
power unit, no FG
¡½
Features :
E L N - 6 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
¢J
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
8.7 ~ 10.5V
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
95 ~ 110%
Protection type : Shut down o/p voltage, re-power on to recover
50ms/230VAC
16ms/115VAC at full load
DIMMING CONTROL
(OPTIONAL)
1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
FUNCTION
File Name:ELN-60-SPEC 2012-12-26
LED OPERATION VOLTAGE
Note.8
3 ~ 9V
Can be adjusted by internal potentiometer SVR1
IP64
( for 48V only)
( except for 48V )
LPS
EMC IMMUNITY
EMC EMISSION
COLD START 60A(t
=600 s measured at 50% I
) at 230VAC
width
peak
£g