© Copyright 2008 Vigitron, Inc.
Technical Specification
*
TEL (+1) 858 - 484 - 5209 • FAX (+1) 858 - 484 - 1205  
13906 Sparren Ave.  San Diego, CA 92129, USA • info@vigitron.com • www.vigitron.com
System Configuration
Ordering Information
PART No.
Description
Vi1416VPD         16-Ch Powered VPD Combiner 
Vi1408VPD         8-Ch Powered VPD Combiner 
*Specifications are subject to change without notice.
1.75"
19"
Camera -1
Camera -2
Camera -3
Camera -4
Camera -5
Camera -6
Camera -7
Camera -8
Video 1-4
Video 5-8
Data 1-4
Data 5-8
Control Room Video
28 V
24 V
Vi1408VPD
Power Out:
24/28 VAC,1A Max/CH
6 A Max Total
8-Ch Powered
VPD Combiner
Vi1408VPD
Control Room Data
Front View
Vi1408VPD
POWER
Rear View
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
Control Room Data Connections:
Pin#
1
2
3
4
5
6
7
8
Data-1 +
Data-1 -
Data-2 +
Data-3  -
Data-3 +
Data-2 -
Data-4 +
Data-4  -
Camera 1-4  Camera 5-8
Data-5 +
Data-5 -
Data-6 +
Data-7  -
Data-7 +
Data-6 -
Data-8 +
Data-8 -
Control Room Video Connections:
Pin#
1
2
3
4
5
6
7
8
Video-1 +
Video-1 -
Video-2 +
Video-3  -
Video-3 +
Video-2 -
Video-4 +
Video-4 -
Camera 1-4  Camera 5-8
Video-5 +
Video-5 -
Video-6 +
Video-7  -
Video-7 +
Video-6 -
Video-8 +
Video-8 -
1
Vi6100VR/Vi6200VR
Vi6104/Vi6204
Vi6108/Vi6208/Vi6308
16
Vi6116/Vi6216/Vi6316
32
Vi6132/Vi6232/Vi6332
Active Receivers
Channels
2,000 feet (610 m) for Vi6200 series
1
16  
32  
750 ft.
228 m 
Vi1004
Vi1008
Vi1016
Vi1032
VB1001F/M
VB1007M
Vi1001F/M/P
Vi1003M
Vi1006M
3,000 ft.
915 m 
Maximum Cable
Distance
Passive Transceivers
Model
Model
Channels
Wire and Cable Recommendations
The Vigitron products are designed to be used with unshielded twisted pair (UTP) wiring. The UTP wire must be 24AWG - 12AWG or Category 2-7 cable. 
Multi pair cable with an overall shield is acceptable, however individually shielded pairs should be avoided. Multiple UTP video feeds can be operated in 
the same communication cable along with telephone, computer, control signals and low power voltages. While UTP video may be routed through 
punch-down block terminals, any resistive, capacitive or inductive devices (such as T-taps or MOV's) must not be used.  Please contact Vigitron for more 
specific information regarding wire types and proper installation techniques. 
Electrical
Input Voltage 
110 VAC or 220 VAC, externally switch selectable
Input Current 
2.4 Amps  (110 VAC) / 1.2 Amps (220 VAC)
Camera Power 
Voltage: Isolated class II, switch selectable
 
 
  24 VAC, off or 28 VAC 
 
Current: 1 A maximum per camera, 6 A maximum aggregated
 
Total power: 170 VA
Fault Protection 
2 A glass fuse (front access) per camera
Twisted Pair (UTP)  100 Ohms +/- 20%, 24 AWG minimum, Category 2-7
Diagnostics LEDs  No load or shut down: 8 red LEDs, one per channel  
 
Power present: 8 green LEDs, one per channel 
Connectors 
Camera connection:  RJ-45 connector
 
Data:  RJ-45 connector
 
Control room video:  RJ-45 connector 
Transient Immunity  per ANSI 587 C62.41
Environmental
Humidity 
0 to 95%, non-condensing
Temperature  
Operating: -20°C to +50°C
 
Storage: -30°C to +70°C
Minimum Airflow 
3 cft./min
Heat 700 
BTU/hour
Mechanical
Dimensions 
1.75x17x12 in., 4.3x43x30.5 cm (HxWxL)
Weight 
12 lb, 5.5 kg
Material 
Steel sheet metal
Included Accessories
Mounting brackets for front, rear or wall installations
Rubber feet for desk applications
Moulded IEC 7-ft. (200 cm) power cord