Supported environment:
Air temperature
Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to 950 m (3,117 ft).
o
Server on: 5 °C to 28 °C (41 °F to 82.4 °F); altitude: 950 m (3,117 ft) to 3,050 m (10,000 ft); 
o
de-rated maximum air temperature 1 °C per 175 m.
Server off: 5 °C to 45 °C (41 °F to 113 °F).
o
Shipment (non-operating): -40 °C to 60 °C (-40 °F to 140 °F).
o
Humidity:
Server on: 8% - 85%, maximum dew point 24 °C (75 °F), maximum rate of change 5 °C/hr.
o
Server off: 8% - 85%, maximum dew point 27 °C (80.6 °F).
o
Shipment: 5% - 100%, maximum dew point 29 °C (84.2 °F).
o
Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
Supports cloud like workload with no performance degradation acceptable (Turbo-Off).
o
Under no circumstance can any combination of worst case workload and configuration result in 
o
system shutdown or design exposure at 40 °C.
The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
o
Electrical
Models with 900 W power supplies:
o
100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 10 A
200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.1 kVA
o
Maximum configuration: 0.9 kVA
o
Models with 750 W hot-swap power supplies:
o
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 8.9 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 4.5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.1 kVA
o
Maximum configuration: 0.75 kVA
o
BTU output
Minimum configuration: 333 Btu/hr (98 watts)
o
Maximum configuration: 3074 Btu/hr (900 watts)
o
Noise level
6.6 bels (operating)
o
6.6 bels (idle)
o