MEAN WELL LPH-18-24 产品宣传页

下载
页码 2
OVER TEMPERATURE
Tj 170
typically (U1) Detect on main control IC
SPECIFICATION
MODEL
LPH-18-12
LPH-18-36
LPH-18-24
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
12V
36V
24V
1.5A
0.5A
0.75A
0 ~ 1.5A
0 ~ 0.5A
0 ~ 0.75A
18W
18W
18W
120mVp-p
200mVp-p
150mVp-p
3.0%
1.0%
2.0%
1500ms, 30ms / 230VAC
47 ~ 63Hz
77%
82%
83%
0.3A/230VAC
0.25mA / 240VAC
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
5. Suitable for indoor use or outdoor use without direct sunlight exposure.
6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
18W Single Output Switching Power Supply










180-264VAC input only
Fully encapsulated with IP67 level (Note.5)
Protections:Short circuit / Over load / Over voltage / Over temperature
Cooling by free air convection
Pass LPS
100% full load burn-in test
Suitable for LED lighting and moving sign applications
High reliability / Low cost
2 years warranty
Class
power unit, no FG
L P H - 1 8
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
File Name: LPH-18-SPEC   2013-04-18
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
Above 105% rated output power
HOLD UP TIME (Typ.)
50ms/230VAC at full load
13.8~ 16.2V
27.6~ 32.4V
41.4 ~ 48.6V
Protection type : Shut off o/p voltage, clamping by zener diode
140*30*22(L*W*H)
COLD START 50A(twidth=155 s measured at 50% Ipeak) at 230VAC
μ
Protection type : Hiccup mode, recovers automatically after temperature goes down
TUV EN60950-1, TUV EN61347-1,EN61347-2-13,IP67 approved; design refer to UL1310 Class 2,CAN/CSA No. 223-M91
1200.6K hrs min.      MIL-HDBK-217F (25
)
0.175Kg; 70pcs/13.3Kgs/0.71CUFT
Features :
IP67
LPS
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
180 ~ 264VAC
254 ~ 370VDC
-30~ +70
℃ (Refer to "Derating Curve")
Compliance to EN55022 (CISPR22)
,
Class B EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,  criteria A
EMC IMMUNITY
EMC EMISSION
F
110