MEAN WELL LPF-60D-24 用户手册

下载
页码 4
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.6
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
12V
7.2 ~12V
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
5A
4A
3A
2.5A
2A
1.67A
1.25A
60W
60W
60W
60W
60W
60.12W
60W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±2.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
1000ms, 80ms / 115VAC at full load     1000ms, 80ms / 230VAC
16ms/230VAC          16ms/115VAC at full load
90 ~ 305VAC          127 ~ 431VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
86%
87%
88%
89%
90%
90%
90%
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes
396.7K hrs min.      MIL-HDBK-217F (25
)
162.5*43*32mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.45Kg; 32pcs/15.4Kg/0.93CUFT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
60W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 90%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class
power unit, no FG
Class 2 power unit
dimming function (1~10Vdc or PWM signal or resistance)
Built-in 3 in 1
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty
Features :
L P F - 6 0 D
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
54V
32.4 ~ 54V
1.12A
60.48W
350mVp-p
±4.0%
±0.5%
±0.5%
42V
25.2 ~ 42V
1.43A
60.06W
250mVp-p
±4.0%
±0.5%
±0.5%
90%
90%
15 ~ 17V
17.5 ~ 21V
23 ~ 27V
28 ~ 35V
34 ~ 40V
41 ~ 49V
54 ~ 63V
0.8A / 115VAC          0.4A / 230VAC          0.32A / 277VAC
46 ~ 54V
59 ~ 66V
File Name:LPF-60D-SPEC   2014-01-15
LPF-60D-12 LPF-60D-15 LPF-60D-20 LPF-60D-24 LPF-60D-30 LPF-60D-36 LPF-60D-42 LPF-60D-48 LPF-60D-54
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25
/ 70% RH
CONSTANT CURRENT REGION
Note.4
IP67
F
M
M
110
SELV
EMC IMMUNITY
Compliance to EN55015, EN61000-3-2  Class C (
60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV),  criteria A
EMC EMISSION
( for 48V,54V only)
( except for 48V,54V )
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V),  EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13
approved ; design refer to UL60950-1, TUV EN60950-1
COLD START 55A(t
=270   s measured at 50% I
) at 230VAC
width
peak
μ