Gepco MP1022 MP1022-0.99 用户手册

产品代码
MP1022-0.99
下载
页码 104
Fiber optic and copper conductor SMPTE 311M hybrid
cable for High Definition video cameras. In the hybrid
311M format, the HD video signal is transmitted over
two single-mode optical fibers to ensure accurate
and extended distance data transmission. To
increase the durability, a special nylon-based
polymer with increased tensile strength is
used for the fiber coatings, and a 16 gage
steel strength member is cabled at the cen-
ter of the cable core. All copper elements
now feature heat-resistant PE insulation
and are shielded by a dense 95% cop-
per braid.  Both extra-flexible and per-
manent installation versions are avail-
able for studio, remote or permanent
installation applications.
Gepco International  
P.
800.966.0069
P.
 847
.795.9555  F
. 847
.795.8770  www
.gepco.com
52
Camera Cables
9.2mm Hybrid Fiber Optic
Features & Benefits
• Ultra-low Attenuation 
• SMPTE 311M Compliant 
• Single Mode Optical Glass Fibers
• Proprietary Fiber Coating for
Increased Tensile Strength 
• Six Copper Conductors
• Heat Resistant
• Strength Member for Additional
Durability
• Copper Braid Shield 
• Extra-flexible TPE or Riser PVC
Jacket
Applications
• High Definition Camera to CCU
Interconnect 
• Portable Cables (HDC920) 
• Permanent Installation
(HDC920R) 
• Studio or Remote Environments
Mechanical Specifications (Series)
Component
Number
Type
Insulation (type, OD)
Color Code
Optical
2
Single Mode 9.5 µ Mode. Field,
125 µ Cladding
CPE Tight Buffer, .9mm
One Blue & One Yellow
Signal
2
24 AWG (7x32) Stranded TC
PE, .045”
One Red & One Gray
Auxiliary
4
20 AWG (19x32) Stranded TC
PE, .060”
Two White & Two Black
Strength Member
1
16 AWG Stranded Steel
PVC, .084”
One White
Mechanical Specifications
Part #
Nominal OD
Master Jacket (type, colors)
Overall Shield
UL Type
Approx. Weight
HDC920
9.20mm
Flexible Thermoplastic, Black
95% TC Braid
AWM
90 lbs/Mft
Extra-flexible Hybrid Camera Cable
HDC920R
9.20mm
PVC, Black
95% TC Braid
CMR
91 lbs/Mft
Permanent Install Hybrid Camera Cable
Electrical & Optical Specifications
Fiber
Attenuation
Signal
Conductor
DCR
Power
Conductor
DCR
Shield
DCR
Insulation
Resistance
(Power or Signal)
Dielectric
Strength
(Power or Signal)
Operating
Temperature
SMPTE
Standard
<0.70 dB/km
@ 1310/1550nm
23.8 S/Mft
9.7 S/Mft
5.4 S/Mft
>10M S/km
3000 Volts RMS
@ 20°C, 60Hz for 1 min.
-40°C to +75°C
(@ 0 to 95% humidity)
311M Compliant
(meets or exceeds)