SPECIFICATION
MODEL
RS-25-3.3
RS-25-5
RS-25-12
RS-25-15
RS-25-24
RS-25-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
Note.4
LOAD REGULATION
Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
3.3V
5V
12V
15V
24V
48V
6A
5A
2.1A
1.7A
1.1A
0.57A
0 ~ 6A
0 ~ 5A
0 ~ 2.1A
0 ~ 1.7A
0 ~ 1.1A
0 ~ 0.57A
19.8W
25W
25.2W
25.5W
26.4W
27.36W
80mVp-p
80mVp-p
120mVp-p
120mVp-p
120mVp-p
200mVp-p
2.85 ~ 3.6V
4.75 ~ 5.5V
10.8 ~ 13.2V
13.5 ~ 16.5V
22 ~ 27.6V
42 ~ 54V
3.0%
2.0%
1.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
2.0%
1.0%
0.5%
0.5%
0.5%
0.5%
1800ms, 23ms/230VAC
4000ms, 30ms/115VAC at full load
80ms/230VAC
14ms/115VAC at full load
88 ~ 264VAC
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
47 ~ 63Hz
73.5%
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
55.2 ~ 64.8V
78.5%
81.5%
83.5%
86%
85%
0.7A/115VAC
0.4A/230VAC
COLD START 30A/230VAC
<2mA / 240VAC
110 ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
UL60950-1, TUV EN60950-1 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
-20 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
309.7Khrs min.
MIL-HDBK-217F (25
)
78*51*28mm (L*W*H)
File Name:RS-25-SPEC 2011-08-19
Protection type : Shut off o/p voltage, clamping by zener diode
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
ENVIRONMENT
SAFETY &
EMC
(Note 6)
PROTECTION
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
25W Single Output Switching Power Supply
R S - 2 5
s e r i e s
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
0.2Kg; 60pcs/13Kg/0.46CUFT
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
No load power consumption<0.5W
Features :
EMC IMMUNITY