D A T A   S H E E T
Specifications
The inlet duct shall be designed using CFD modeling and actual thermal lab 
verification, and shall be compatible with Cisco Nexus^ 9396 and Nexus^ 
93128. The inlet duct shall optimize thermal performance by directing air from 
the cold aisle to the switch inlet preventing hot air recirculation. The use of 
passive inlet duct shall lower the average switch inlet temperature by 12oF to 
22oF; resulting in reduced energy costs. The modular duct shall be capable of 
being installed in retro-fit applications and allow access to fan and power 
supply modules without disrupting existing in-cabinet equipment and cabling.
Key Features and Benefits
Direct cool air to the switch: Increases energy efficiency in ToR applica-
tions and allows high density server applications
Passive inlet duct: No additional moving parts or power required
Day one or two installation: Eliminates the requirement to replace or disturb 
existing cabinets, equipment and infrastructure for lower capital expenditures 
and minimized risk
Compatible with Panduit Server (S-Type) Cabinets: Allows maximum  
thermal efficiency
Allows for installation in cabinets with mounting depths from 24 – 30" 
(610 – 762mm): Allows greater network flexibility and reliability
Allows access to power supplies and fan blades: Allows ease  
of maintenance
Bracket supports switch during installation: Allows single person ease of 
switch installation
Technical Information
Dimensions:
DIFBA2002S00S (2 RU): 
29"-30"D (adjustable) x 3.50"H x 18.3"W  
(736.6 - 762mm D x 88.9mm H x 465mm W)
DIFBA3003S00S (3 RU): 29"-30"D (adjustable) x 5.25"H x 18.3"W  
(736.6 - 762mm D x 133.35mm H x 465mm W)
Thermal Inlet Ducts for Cisco Nexus^ 9396 and 93128 
Switches for Net-Access
 S-Type Cabinets 
Applications
Top of Rack (ToR) switches, such as the Cisco Nexus^ 9000 series, are designed to meet the server-access networking  
requirements of the virtualized data center. When deployed within server cabinets, the modular duct provides a cool air path  
to the air intakes of the switch. By providing a path for cool air to the switch, data center temperature set points can be raised – 
resulting in higher energy efficiencies and lower operating costs.
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
cs-emea@panduit.com
Phone: 44.20.8601.7200
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
PANDUIT JAPAN
Tokyo, Japan
cs-japan@panduit.com
Phone: 81.3.6863.6000
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
Phone: 52.33.3777.6000
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
©2015 Panduit Corp.
ALL RIGHTS RESERVED.
RKDS09--WW-ENG
1/2015
For more information
Visit us at www.panduit.com
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300
^Cisco and Cisco Nexus are registered trademarks and Cisco ACI is a trademark of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
Inlet Duct for Top-of-Rack Switch Applications
Nexus^ 9396PX - DIFBA2002S00S
Nexus^ 9396TX - DIFBA2002S00S
Nexus^ 93128TX - DIFBA3003S00S