Eaton Powerware 9355-40-N-12-4x9Ah 1025800 产品宣传页

产品代码
1025800
下载
页码 2
Eaton 9355 UPS 20 - 40 kVA
In the interests of continuous product improvement all specifications are subject to change without notice.
Technical specificaTions
UPS output power rating (0,9 p.f.)
kVA
   20
30
40
kW
   18
27
36
General
Efficiency in double  
conversion mode (full load)
93%
Efficiency in double  
conversion mode (half load) 91%
Distributed parallelling with 
Hot Sync technology
4
Field upgradeable
yes
Inverter/rectifier topology
transformer-free IGBT with PWM
Audible noise
<50 dB
Altitude (max)
1000 m without derating (max 2000 m)
Input
Input wiring
3 ph + N + PE
Nominal voltage rating  
(configurable)
220/380, 230/400, 240/415 V 50/60 Hz
Input voltage range
Low -20% at 100% load/-50% at 50% load without 
battery discharge; High +10%/max +20%
Input frequency range
45-65 Hz
Input power factor
0,99
Input ITHD
less than 4,5%
Soft start capability
Yes
Internal backfeed protection Yes
Output
Output wiring
1 ph or 3 ph + N + PE
Nominal voltage rating  
(configurable)
220/380, 230/400, 240/415 V 50/60 Hz
Output UTHD 
<3% (100% linear load); <5% (reference non 
linear load)
Output power factor
0,9 (e.g. 27 kW at 30 kVA)
Permitted load power factor 0,7 lagging - 0,8 leading
Overload on inverter
10 min 100-110%; 1 min 110-125%;  
5 sec 125-150%; 300 ms >150%
Overload when bypass 
available
60 min 100-110%, 10 min 110-125%; 1 min >125-
150%
Battery
Type
Maintenance free VRLA batteries, NiCd
Charging method
ABM technology or Float
Temperature compensation
Optional
Battery nominal voltage 
(lead-acid)
432 V (36x12 V, 216 cells)
Charging current / Model
Default 3 A
 
*Max 60 A
*May be limited by maximum UPS input current rating
Accessories
Isolation transformer, long-life batteries, external 
battery cabinets, X-Slot connectivity (Web/SNMP, 
ModBus/Jbus, Relay, Hot Sync, ViewUPS-X 
remote display), Hot Sync parallel tie cabinet, 
integrated manual bypass, external maintenance 
bypass switch
Communications
X-Slot
2 communication bays
Serial ports
1 available
Relay inputs/outputs
2/1 programmable
Compliance with standards
Safety (CB certified)
IEC 62040-1, IEC 60950-1
EMC
IEC 62040-2
Performance
IEC 62040-3
Standard UPS with 3-phase input
Part number 9355
Description
Rating
Runtime (pf 0.7)
Dimensions (HxWxD)
Weight
1025061/1026598
9355/9155-20-N-5-1x9Ah-MBS
20 kVA / 18 kW
5 min
1684x494x762 mm
300 kg
1025062/1026599
9355/9155-20-N-13-2x9Ah-MBS
20 kVA / 18 kW
13 min
1684x494x762 mm
400 kg
1025063/1026600
9355/9155-20-N-22-3x9Ah-MBS
20 kVA / 18 kW
22 min
1684x494x762 mm
500 kg
1025064/1026601
9355/9155-20-N-31-4x9Ah-MBS
20 kVA / 18 kW
31 min
1684x494x762 mm
600 kg
1025065/1026602
9355/9155-30-N-7-2x9Ah-MBS
30 kVA / 27 kW
7 min
1684x494x762 mm
400 kg
1025066/1026603
9355/9155-30-N-13-3x9Ah-MBS
30 kVA / 27 kW
12 min
1684x494x762 mm
500 kg
1025067/1026604
9355/9155-30-N-20-4x9Ah-MBS
30 kVA / 27 kW
20 min
1684x494x762 mm
600 kg
1025795
9355-40-N-8-3x9Ah-MBS
40 kVA / 36 kW
8 min
1684x494x762 mm
517 kg
1025796
9355-40-N-12-4x9Ah-MBS
40 kVA / 36 kW
12 min
1684x494x762 mm
617 kg
External battery cabinets 9155/9355
Part number
Description
Rating
Runtime
Dimensions (HxWxD)
Weight
1025169
9355-BAT-1x24Ah
1x36x24 Ah
See separate  
specification
1684x494x758 mm
510 kg
1025170
9355-BAT-2x24Ah 
2x36x24 Ah
1684x494x758 mm
870 kg
9355 20-40 kVa runtimes
Runtimes for UPS with internal batteries ...p.f. 0.7 (typical IT server/computer load)
Battery
Qty
5
10
15
20
25
30
35
40
kVA
7 Ah 12 V
1 x 36
24
8
5
-
-
-
-
-
min
9 Ah 12 V
1 x 36
30
12
7
5
-
-
-
-
min
7 Ah 12 V
2 x 36
60
24
14
10
6
-
-
-
min
9 Ah 12 V
2 x 36
70
28
18
13
10
7
5
-
min
7 Ah 12 V
3 x 36
103
41
26
17
12
10
7
5
min
9 Ah 12 V
3 x 36
115
46
31
22
16
13
10
8
min
7 Ah 12 V
4 x 36
152
55
40
26
18
15
11
9
min
9 Ah 12 V
4 x 36
158
63
42
31
23
20
15
12
min
© 2010 Eaton Corporation, All Rights Reserved, 00DATA1018101 rev C, September 2010