Avaya Integral 5 Easy BNS AR2.X 4999108496 用户手册
产品代码
4999108496
06/07
228
4.999.112.593
Installation manual Integral 5 D/E easy
Commissioning
Upgrading / reconfiguring modules
Every time a change is made (unplugging a module / plugging a module in), the system configuration should be read in again using code 0
Upgrading / reconfiguring modules
Connecting and Disconnecting Under
Voltage:
Using code *0
Code *0 is a code number issued to the customer, it allows the software
version identities to be displayed.
The system data is displayed in the form Lx Ty by pressing the speed
dialling key. (x = number of lines; y = number of subscribers.)
The CD function is extended at this stage.
If the CD function is called up by service data input (service registration with
CD**), the PSW is activated after the Lx Ty output. The message described
above is sent to the PSW of the BUxs.
The PSW sends acknowledgement when the configuration data has been
read.
When the acknowledgement is received, (the cursor is positioned at the
10th position in the display and) the Lx Ty output is repeated.
If no acknowledgement is received, it is still possible to operate the CD
function or to leave it.
So that this function can be used from an end terminal without a speed
dialling key, the function can also be activated using the redial key.