Rigol DS1104Z 4-channel oscilloscope, Digital Storage oscilloscope, DS1104Z 用户手册

产品代码
DS1104Z
下载
页码 264
RIGOL 
DS1000Z User’s Guide 
7-6 
Start Bit
Data Bit
Check Bit
Stop Bit
 
Start Bit: represent when the data starts outputting. Setting the Polarity is 
equivalent to specifying the “Start Bit”. 
Data Bits: represent the number of data bits actually contained in each frame of 
data. 
Check Bit: used to check the correctness of the data transmission. 
  Odd Checkout: the number of “1” in the data bit and check bit is an odd. For 
example, when 0x55 (01010101) is sent, a 1 needs to be filled in the check bit to 
make the number of 1 be an odd.   
  Even Checkout: the number of “1” in the data bit and check bit is an even. For 
example, when 0x55 (01010101) is sent, a 0 should be filled in the check bit. 
  None: there would not be check bit during the transmission. 
 
Press MATH  Decode1  Decoder to select “RS232” and open the RS232 
decoding function menu. 
 
1.  Press Decode to turn on or off the decoding function. 
 
2.  TX and RX Channel Setting 
Press TX to select any channel (CH1-CH4) as the transmitting channel and when 
“OFF” is selected, no transmitting channel is set. Use the same method the set 
the RX channel.   
 
3.  Polarity Setting 
Press Polarity to select “
” or “
” and the default is normal. The 
oscilloscope will select the rising or falling edge as the start position during 
decoding. 
 
4.  Baud Rate Setting 
Press Baud use    to select the desired baud rate and you also can press 
Preset to select 2400, 4800, 9600, 57600, 115200, 230400, 460800, 921600 
and 1000000 and the default is 9600, the unit is bps. 
5.  Endian Setting