Slope Trigger 
 
Trigger on the positive or negative slope of specified time.   
 
Trigger Type: 
Press Type to select “Slope”. At this point, the trigger setting information as shown 
in the figure below is displayed at the upper right corner of the screen. 
 
 
Source Selection:   
Press Source to select CH1-CH4 as the 
. The current trigger source 
is displayed at the upper right corner of the screen. 
Note: select channel with signal input as trigger source to obtain stable trigger. 
 
Slope Condition:   
Press When to select the desired slope condition. 
 
: trigger when the positive slope time of the input signal is greater than 
the specified time. 
 
: trigger when the positive slope time of the input signal is lower than the 
specified time. 
 
: trigger when the positive slope time of the input signal is greater than 
the specified lower limit of time and lower than the specified upper limit of time. 
 
: trigger when the negative slope time of the input signal is greater than 
the specified time. 
 
: trigger when the negative slope time of the input signal is lower than 
the specified time. 
 
: trigger when the negative slope time of the input signal is greater than 
the specified lower limit of time and lower than the specified upper limit of time. 
 
Time Setting: 
In this oscilloscope, positive slope time is defined as the time difference between the 
two crossing points of trigger level line A and B with the positive edge as shown in 
the figure below.