Rigol DS1104B 4-channel oscilloscope, Digital Storage oscilloscope, DS1104B 用户手册

产品代码
DS1104B
下载
页码 164
RIGOL 
©  2008 RIGOL Technologies, Inc. 
  User‟s Guide for DS1000B series 
2-82 
Waveform Recorder
 
Waveform recorder records input waveforms from CH1, CH2, CH3 and CH4 with a 
maximum record length of 1000 frames. This performance can also be activated by 
the  Pass/Fail  test  output,  which  makes  this  function  especially  useful  to  capture 
abnormal signals in long term without keeping an eye watching it. 
Press Utility→RecordModeRecord to go to the following menu 
Waveform recorder: Record the waveforms with specified interval. 
 
Figure 2-104      Table 2-69 The Record menu (Page 1/2) 
Menu 
Settings 
Comments 
Mode 
OFF 
Record 
Play back 
Storage 
Select record mode. 
Select play back mode. 
Select storage mode. 
Turn off all recorder functions. 
Source 
CH1, CH2 
CH3, CH4 
P/F-OUT 
Select record source channel. 
End Frame 
 
<1-1000> 
Set number of record frames. 
Operate 
  (Run) 
 
  (Stop) 
Record  stopped,  press  to  Start 
recording. 
Press to stop recording. 
 
Figure 2-105      Table 2-70 The Record menu (Page 2/2) 
Menu 
Settings 
Comments 
Interval 
 
<1.00ms-1000s> 
Set  time  interval  between 
record frames.