RMON Configuration
363
With the history data management function, you can configure network devices 
to collect history data, sample and store data of a specific port periodically.
Statistics group
Statistics group contains the statistics of each monitored port on a switch. An 
entry in a statistics group is an accumulated value counting from the time when 
the statistics group is created.
The statistics include the number of the following items: collisions, packets with 
cyclic redundancy check (CRC) errors, undersize (or oversize) packets, broadcast 
packets, multicast packets, and received bytes and packets.
With the RMON statistics management function, you can monitor the use of a 
port and make statistics on the errors occurred when the ports are being used.
RMON Configuration
Before performing RMON configuration, make sure the SNMP agents are correctly 
configured. For the information about SNMP agent configuration, refer to 
“Configuring Basic SNMP Functions” on page 353.
Table 279   Configure RMON
Operation 
Command 
Description 
Enter system view 
system-view 
Add an event entry 
rmon event event-entry [ 
description string ] { log | 
trap trap-community | 
log-trap log-trapcommunity | 
none } [ owner text ] 
Optional 
Add an alarm entry 
rmon alarm entry-number 
alarm
-variable sampling-time { 
delta | absolute } 
rising_threshold 
threshold-value1 event-entry1 
falling_threshold 
threshold-value2 event-entry2 
owner text ] 
Optional
Before adding an alarm entry, 
you need to use the rmon 
event
 command to define the 
event to be referenced by the 
alarm entry. 
Add an extended alarm entry  rmon prialarm entry-number 
prialarm-formula prialarm-des 
sampling-timer
 { delta | 
absolute | changeratio } 
rising_threshold 
threshold-value1 event-entry1 
falling_threshold 
threshold-value2 event-entry2 
entrytype { forever | cycle 
cycle-period } [ owner text ] 
Optional
Before adding an extended 
alarm entry, you need to use 
the rmon event command to 
define the event to be 
referenced by the extended 
alarm entry. 
Enter Ethernet port view 
interface interface-type 
interface-number 
Add a history entry 
rmon history entry-number 
buckets number interval 
sampling-interval [ owner 
text ] 
Optional 
Add a statistics entry 
rmon statistics entry-number 
owner text ] 