Telnet Configuration with Authentication Mode Being Scheme
49
# Configure Telnet protocol is supported.
[4210-ui-vty0] protocol inbound telnet
# Set the maximum number of lines the screen can contain to 30.
[4210-ui-vty0] screen-length 30
# Set the maximum number of commands the history command buffer can store
to 20.
to 20.
[4210-ui-vty0] history-command max-size 20
# Set the timeout time to 6 minutes.
[4210-ui-vty0] idle-timeout 6
Telnetting to a Switch
Telnetting to a Switch from a Terminal
1 Assign an IP address to VLAN-interface 1 of the switch (VLAN 1 is the default
VLAN of the switch).
■
Connect the serial port of your PC/terminal to the Console port of the switch,
as shown in Figure 12.
as shown in Figure 12.
Figure 12 Diagram for establishing connection to a Console port
■
Launch a terminal emulation utility (such as Terminal in Windows 3.X or
HyperTerminal in Windows 95/Windows 98/Windows NT/Windows
2000/Windows XP) on the PC terminal, with the baud rate set to 9,600 bps,
data bits set to 8, parity check set to none, and flow control set to none.
HyperTerminal in Windows 95/Windows 98/Windows NT/Windows
2000/Windows XP) on the PC terminal, with the baud rate set to 9,600 bps,
data bits set to 8, parity check set to none, and flow control set to none.
■
Turn on the switch and press Enter as prompted. The prompt (such as <4210>)
appears, as shown in the following figure.
appears, as shown in the following figure.
RS-232 port
Configuration cable