Omron G2R-1-SNI 230 VAC PCB Mount Relay 230Vac 1 CO, SPDT G2R-1-SNI 230 VAC 数据表

产品代码
G2R-1-SNI 230 VAC
下载
页码 19
G2R
G2R
19
Precautions
Mounting
When mounting a number of relays on a PCB, be sure to provide a
minimum mounting space of 5 mm between the two juxtaposed re-
lays as shown below.
5 mm min.
5 mm min.
The above minimum mounting space is necessary due to mutual
thermal interference generated by the relays. This restriction may
be ignored, however, depending on the operating conditions of the
relays. Consult OMRON for details.
There is no restriction on the mounting direction of each relay on the
PCB.
When using this circuit, confirm the set and reset states and then
take into account the circuit constant.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K013-E1-11B