TE Connectivity RT314012 PCB Mount Relay 12Vdc 16A 1 CO, SPDT 9-1393239-5 数据表
产品代码
9-1393239-5
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
change.
General Purpose Relays
1
Power PCB Relay RT1
I
1 pole 12 / 16 A, 1 CO or 1 NO contact
I
DC- or AC-coil
I
Sensitive coil 400 mW
I
5 kV / 10 mm coil-contact, reinforced insulation
I
Ambient temperature 85°C (DC-coil)
I
WG version: Product in accordance to IEC60335-1
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0413
as per product date code 0413
Applications
Boiler control, timers, garage door control, POS automation,
interface modules
interface modules
F0144-B
Approvals
V
REG.-Nr. 6106,
Z
E214025,
B
C0786,
S
0039110/01-02,
F
FI 190164 A1,
H
98.4118.01
Technical data of approved types on request
Contact data
Contact configuration
1 CO or 1 NO contact
Contact set
single contact
Type of interruption
micro disconnection
Rated current
12 A
16 A
Rated voltage / max.switching voltage AC
240/400 VAC
Limiting continuous current
UL: 20 A
Maximum breaking capacity AC
3000 VA
4000 VA
Limiting making capacity, max 4 s, df 10%
25 A
30 A
Contact material
AgNi 90/10, AgNi 90/10 gold plated
Mechanical endurance DC coil
> 30 x 10
6
cycles
AC coil
> 10 x 10
6
cycles
Rated frequency of operation with / without load
6 / 1200 min
-1
Contact ratings
Type
Type
Load
Cycles
RT314
16 A, 250 VAC, NO contact, 85°C, DF 10%, UL508
50x10
3
RT314
16 A, 250 VAC, NC contact, 70°C, 30min
-1
53x10
3
RT314
20 A, 250 VAC, NO contact, 85°C, UL508
6x10
3
RT314
1000 W incandescent lamp, 250 VAC
1.2x10
3
RT314
10 A, 250 VAC, cos
ϕ=0.6, CO contact, 70°C
200x10
3
RT314
5 A / 2 A, 250 VAC, cos
ϕ=1, motor, NO contact, 10min
-1
, 70°C
1.1x10
6
RT314
0.26 A / 0.01 A, 230 VAC, cos
ϕ=0.38, valve, NO contact, 25min
-1
7.6x10
6
RT314
Pilot duty A300 (NO contact), B300 (CO/NC contact), UL508
RT314
1hp @ 240 VAC, 1/2hp @ 120 VAC, NO contact, UL508
RT314
AC15, 6 A, 250 VAC, NO and NC contact, 85°C, EN60947-5-1
RT314
DC13, 2 A / 24 VDC, 0.2 A / 250 VDC, NO and NC contact, 85°C, EN60947-5-1
Coil data
Rated coil voltage range DC coil
5...110 VDC
AC coil
24...230 VAC
Coil power DC coil
typ 400 mW
AC coil
typ 0.75 VA
Operative range
2
Coil insulation system according UL1446
class F