Panasonic AEP19012 PCB Mount Relay 1 NO, SPST-NO AEP19012 数据表

产品代码
AEP19012
下载
页码 8
EP
2. Specifications
*2 Conditions: Varistor used for coil surge absorption. Note: if a diode is used the life will be lower.
*3 Condition: Switches rated number of 10 cycles each time there is a 2,500A cutoff.
REFERENCE DATA
Characteristics
Item
Specifications
10A type
60A type
80A type
300A type
Rating
Arrangement
1 Form A
1 Form A
1 Form A
1 Form A
Nominal switching capacity (resistive load)
10A 400V DC
60A 400V DC
80A 400V DC
300A 400V DC
Short term current
15A (2min), 
30A (30s)
120A (15min) 
(harness wire: 15mm
2
)
400A (10min) 
(harness wire: 
100mm
2
)
Max. cut-off current
600A 300V DC 
(5 cycles)*
2
800A 300V DC 
(1 cycle)*
2
2,500A 300V DC 
(3 cycles)*
3
Overload opening/closing rating
30A 400V DC 
(Min. 50 cycles)*
2
180A 400V DC 
(Min. 100 cycles)*
2
120A 400V DC 
(Min. 50 cycles)*
2
600A 400V DC 
(Min. 300 cycles)
Reverse cut-off current
–10A 200V DC 
(Min. 2.5
×10
3
 cycles)*
2
–60A 200V DC 
(Min. 1,000 cycles)*
2
–120A 200V DC 
(Min. 50 cycles)*
2
–300A 200V DC 
(Min. 100 cycles)
Min. switching capacity
1A 6V DC
Contact voltage drop
Max. 0.5V 
(When current 
[is 10A per 1] 
contact set)
Max. 0.1V 
(When current 
[is 60A per 1] 
contact set)
Max. 0.067V 
(By voltage drop 
6V DC 20A)
Max. 0.06V 
(When current 
[is 300A per 1] 
contact set)
Electrical 
characteristics
Insulation resistance (Initial)
Min. 100M
Ω (at 500V DC) 
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage 
(Initial)
Between open contacts
2,500 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil
2,500 Vrms for 1min. (Detection current: 10mA.)
Operate time (at 20
°C 
68
°F
)
Max. 50ms 
(Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 30ms 
(Nominal voltage 
applied to the coil, 
excluding contact 
bounce time.)
Release time (at 20
°C 
68
°F
)
Max. 30ms (After the nominal operation voltage stops)
Max. 10ms 
(After the nominal 
operation voltage 
stops)
Mechanical 
characteristics
Shock resistance
Functional
Min. 196 m/s
2
 (Half-wave pulse of sine wave: 11 ms; detection time: 10
µs.)
Destructive
Min. 490 m/s
2
 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional
10 to 200Hz, acceleration 43m/s
2
 constant (Detection time: 10
µs.)
Destructive
10 to 200Hz, acceleration 43m/s
2
 constant (3 directions,each 4 hours)
Expected life
Mechanical
Min. 10
5
Min. 2
×10
5
Electrical
7.5
×10
4
 
10A 400V DC*
2
 
L/R
1ms
3
×10
3
 
60A 400V DC*
2
 
L/R
1ms
10
3
 
80A 400V DC*
2
 
L/R
1ms
10
3
 
300A 400V DC 
L/R
1ms
Conditions
Conditions for operation, transport and storage*
1
Ambient temperature: –40
°C to +80°C 
–40
°F to +176°F
 (Storage: Max. 85
°C 
185
°F
), 
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight
Approx. 80 g 
2.820oz
Approx. 340 g 
12.00oz
Approx. 400 g 
14.11oz
Approx. 750 g 
26.46oz
1.-(1) Ambient temperature characteristics 
(10A type)
Tested sample: 10A type EP relay, 3pcs
1.-(2) Ambient temperature characteristics 
(60A type)
Tested sample: 60A type EP relay, 3pcs
1.-(3) Ambient temperature characteristics 
(80A type)
Tested sample: 80A type EP relay, 3pcs
x
-40
-40
-30
-20
-10
40
30
20
10
0
-40
80
146
60
110
40
74
20
68
-20
Ambient 
temperature, 
°C
°F
Pick up 
voltage
Drop out 
voltage
Variation  ratio, %
-4
0
32
x
x
x
-40
-40
-30
-20
-10
40
30
20
10
-40
80
146
60
110
40
74
20
68
-20
Ambient 
temperature, 
°C
°F
Pick up 
voltage
Drop out 
voltage
Variation  ratio, %
-4
0
32
Ambient
temperature,
°C    
°F
-40
-40
-30
-20
-10
40
30
20
10
-40
80
146
60
110
40
74
20
68
-20
Pick up 
voltage
Drop out 
voltage
Operate 
time
Release 
time
Variation  ratio, %
-4
0
32
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.