MEAN WELL LED driverLED-switching power supply APC-12-350 APC-12-350 数据表

产品代码
APC-12-350
下载
页码 3
SPECIFICATION
MODEL
APC-12-350
APC-12-700
DC VOLTAGE RANGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER VOLTAGE
9~36V
9~18V
350mA
700mA
12.6W
12.6W
300mVp-p
250mVp-p
±5.0%
±1.0%
±3.0%
3000ms, 180ms / 230VAC         3000ms, 150ms / 115VAC at full load
47 ~ 63Hz
82%
80%
0.2A/230VAC;0.35A/115VAC
0.25mA / 240VAC
-30 ~ 70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.2%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristic for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
7. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently 
      connected to the mains.
12W Single Output Switching Power Supply

Constant current design

Universal AC input / Full range  

Protections:Short circuit / Over voltage

Fully isolated plastic case

Small and compact size

Cooling by free air convection

Class   power unit, no FG

Class 2 power unit

Pass LPS

IP30 design

Suitable for LED lighting and moving sign applications

100% full load burn-in test

Low cost / High reliability

2 years warranty
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
File Name: APC-12-SPEC   2014-09-22
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
EMC IMMUNITY
Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV),  criteria A
EMC EMISSION
HOLD UP TIME (Typ.)
20ms/230VAC,15ms/115VAC  at full load
39.6~ 46.8V
20.7~ 24.3V
Protection type : Shut off o/p voltage, clamping by zener diode
77*40*29(L*W*H)
COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VAC
μ
UL8750,CSA C22.2 No.250.0-08 approved, Design refer to TUV EN61347-1
1145.7K hrs min.      MIL-HDBK-217F (25
)
0.08Kg; 120pcs/11.8Kg/1.06CUFT
 Features :
LPS
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
90 ~ 264VAC          127 ~ 370VDC
APC-12
series
CURRENT ACCURACY
±8.0%
110
SELV
F
(
)
Note.7