Intel SC5400LXI 用户手册

下载
页码 104
Chassis Power Subsystem 
Intel® Server Chassis SC5400 5U Kit TPS
 
32  
Revision: 
1.0 
 
5.1.5.3 Voltage 
Regulation 
The output voltages must stay within the following voltage limits when operating at steady state 
and dynamic loading conditions. These limits include the peak-peak ripple/noise. All outputs are 
measured with reference to the return remote sense signal (Returns). The +12V3, +12V4, –12V 
and 5VSB outputs are measured at the power supply connectors referenced to Returns. The 
+3.3V, +5V, +12V1, and +12V2 are measured at the remote sense signal located at the signal 
connector. 
Table 22. Voltage Regulation Limits 
Parameter 
Tolarance 
Minimum 
Nominal 
Maximum 
Units 
+3.3V 
- 5% / +5% 
+3.14 
+3.30 
+3.46 
V
rms
 
 +5V 
- 5% / +5% 
+4.75 
+5.00 
+5.25 
V
rms
 
+12V1 
- 5% / +5% 
+11.40 
+12.00 
+12.60 
V
rms
 
+12V2 
- 5% / +5% 
+11.40 
+12.00 
+12.60 
V
rms
 
+12V3 
- 5% / +5% 
+11.40 
+12.00 
+12.60 
V
rms
 
+12V4 
- 5% / +5% 
+11.40 
+12.00 
+12.60 
V
rms
 
- 12V 
- 5% / +9% 
- 11.40 
-12.00 
-13.08 
V
rms
 
+5VSB 
- 5% / +5% 
+4.75 
+5.00 
+5.25 
V
rms
 
 
5.1.5.4 Standby 
Operation 
The 5V standby output is present when an AC input greater than the power supply turn on 
voltage is applied.  
The power supply fan is off (fan-less operation) when the power supply is in the stand-by mode 
of operation. The power supply will work indefinitely in stand-by mode with the input AC power 
on, power supply off, and the 5V stand-by output at full load (= 3A).  
5.1.6 
670W Protection Circuits 
Protection circuits inside the power supply shall cause only the power supply’s main outputs to 
shutdown. If the power supply latches off due to a protection circuit tripping, an AC cycle OFF 
for 15 seconds and a PSON# cycle HIGH for one second shall be able to reset the power 
supply. 
5.1.6.1 
Over Voltage Protection  
The power supply shall shutdown and latch off after an over voltage condition occurs. The 
voltage shall never exceed the maximum levels when measured at the power pins of the power 
supply connector during any single point of fail. The voltage shall never trip any lower than the 
minimum levels when measured at the power pins of the power supply connector. 5Vsb (stand-