MEAN WELL LPV-60-24 数据表

下载
页码 2
SPECIFICATION
MODEL
LPV-60-5
LPV-60-12
LPV-60-15
LPV-60-24
LPV-60-36
LPV-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V
12V
15V
24V
36V
48V
8A
5A
4A
2.5A
1.67A
1.25A
0 ~ 8A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
0 ~ 1.67A
0 ~ 1.25A
40W
60W
60W
60W
60W
60W
80mVp-p
120mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
±8.0%
±1.0%
±6.0%
90 ~ 264VAC          127 ~ 370VDC
47 ~ 63Hz
76%
83%
±2.0%
±5.0%
83%
86%
86%
86%
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
41.4 ~ 48.6V
55.2 ~ 64.8V
1.2A/115VAC     1A/230VAC
COLD START 60A(twidth=525 s measured at 50% Ipeak) at 230VAC
μ
0.25mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,  criteria A
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes
732Khrs min.      MIL-HDBK-217F (25
)
162.5*42.5*32mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
0.4Kg; 32pcs/13.8Kg/0.56CUFT
Protection type : Shut down o/p voltage, re-power on to recover
60W Single Output Switching Power Supply
 Features :
L P V- 6 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
File Name:LPV-60-SPEC   2012-12-26

Constant voltage design

Universal AC input / Full range

Withstand 300VAC surge input for 5 seconds

Protections: Short circuit / Over load / Over voltage 

Cooling by free air convection

Fully encapsulated with IP67 level 
(Note.8)

Fully isolated plastic case

Class   power unit, no FG

Class 2 power unit

ass LPS
P

Suitable for LED lighting and moving sign applications 
(Note.7)

100% full load burn-in test

Low cost, high reliability

2 years warranty
500ms, 20ms / 230VAC    500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC    500ms, 30ms / 115VAC at full load(for 48V)
50ms/230VAC          16ms/115VAC at full load
EMC IMMUNITY
EMC EMISSION
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48),
CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1
( for 48V only)
( except for 5V,48V )
IP67
LPS