SPECIFICATION
MODEL
CLG-60-12
CLG-60-15
CLG-60-20
CLG-60-24
CLG-60-27
CLG-60-36
CLG-60-48
DC VOLTAGE
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
12V
15V
20V
24V
27V
36V
48V
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.7A
0 ~ 1.3A
60W
60W
60W
60W
62.1W
61W
62.5W
2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
2.7Vp-p
3.6Vp-p
4.6Vp-p
10%
Fixed can be modified between the range above
Fixed. Can be modified between 3% ~ -25% rated output current
3.0%
5.0%
3000ms / 230VAC 5000ms / 115VAC at full load
90 ~ 295VAC
127 ~ 417VDC
47 ~ 63Hz
PF
0.9 at 75 ~ 100% load, 115VAC / 230VAC
85%
86%
87.5%
87%
88%
89%
89%
13.8 ~ 16V
17.5 ~ 21V
23 ~ 26V
28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
0.8A/115VAC
0.4A/230VAC
40A/230VAC
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70
(Refer to output load derating curve)
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
495.7Khrs min.
MIL-HDBK-217F (25
)
195.6*61.5*38.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with “RIPPLE & NOISE”  > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
0.86Kg; 16pcs/14.8Kg/0.54CUFT
Protection type : Shut down o/p voltage, re-power on to recover
60W Single Output LED Power Supply
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Pass LPS
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
3 years warranty
(up to 295VAC)
Suitable for dry / damp / wet locations
(Note.2)
High efficiency 89%
Features :
C L G - 6 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
12V: 90
10
(TSW1) detect on heatsink of power transistor
15V ~ 48V: 85
10
(TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
File Name:CLG-60-SPEC 2011-01-03
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
UL879, UL8750, UL1310 Class 2, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V) ;
J61347-1, J61347-2-13(20~27only), IP67 approved
I/P-O/P:100M Ohms / 500VDC / 25
/ 70% RH
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to
Class C (
75% load) ; EN61000-3-3
EN61000-3-2
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A
EMI CONDUCTION & RADIATION
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
8.4 ~ 12V
RATED CURRENT
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
CONSTANT CURRENT REGION
Note.5
11.5 ~ 13V
14.5 ~ 16.2V
19.5 ~ 22V
24 ~ 26V
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
IP67
( for 48V only)
( except for 48V )
F
M
M
110
LPS
SELV
( for 20~27V only)
P S
E