Finder 65.31.8.024.0000 20 SPST-NO, SPST-NC 24 Vac 65.31.8.024.0000 数据表

产品代码
65.31.8.024.0000
下载
页码 6
3
Example: 65 series power relay, PCB with bifurcated terminals, 1 NO + 1 NC (SPST-NO + SPST-NC) contact, 12 V DC coil. 
Ordering information
A: 
Contact material
0 = Standard AgCdO
4 = AgSnO
2
B: 
Contact circuit
0 = 1 NO + 1 NC
(SPST-NO + SPST-NC)
3 = NO (≥ 3 mm contact gap)
Series
Type
3 = Faston 250 (6.3x0.8 mm)  
with rear flange mount 
6 = PCB with bifurcated terminals
No. of poles
1 = 1 NO + 1 NC (SPST-NO + SPST-NC)
Coil version
8 = AC (50/60 Hz) 
9 = DC
Coil voltage
See coil specifications
6
1
0
0
9
D: 
Special versions
0 = Standard
9 = Type 65.31 without rear flange 
mount
C: 
Options
0 = None
0
0
A
B
C
D
.
.
.
.
0 1 2
6 5
Insulation according to EN 61810-1
1 NO + 1 NC
1 NO
Nominal voltage supply system
V AC
230/400
230/400
Rated insulation voltage
V AC
250
400
250
400
Pollution degree
3
2
3
2
Insulation between coil and contact set
Type of insulation
Basic
Basic
Overvoltage category
III
III
Rated impulse voltage
kV (1.2/50 µs)
4
4
Dielectric strength
V AC
2,500
2,500
Insulation between open contacts
Type of disconnection
Micro-disconnection
Full-disconnection
Overvoltage category
III
Rated impulse voltage
kV (1.2/50 µs)
4
Dielectric strength
V AC/kV (1.2/50 µs)
1,500/2
2,500/4
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2
EN 61000-4-4
level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode)
EN 61000-4-5
level 4 (4 kV)
Other data
Bounce time: NO/NC
ms
5/6 (1 normally open + 1 normally closed) 7/— (normally open) 
Vibration resistance (10…150)Hz: NO/NC
g
20/13
Shock resistance
g
20
Power lost to the environment
without contact current
W
1.3
with rated current
W
2.1 (65.31, 65.61)
3.1 (65.31/.61.0300)
Recommended distance between relays mounted on PCB 
mm
≥ 
5
Technical data
65 Series - Power relays 20 - 30 A
Type
Coil version A
B
C
D
65.31
AC-DC
- 4
- 3
0
-  9
65.61
AC-DC
- 4
- 3
0
0
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.