Finder 86.30.0.024.0000 - Timer Module 86.30.0.024.0000 数据表

产品代码
86.30.0.024.0000
下载
页码 12
2
86 Series - Timer modules 
Example: 86 series multi-function timer module, (12...240)V AC/DC supply voltage.
Ordering information
Number of poles
Relay type
Socket type
Timer module
1
40.31
95.03
86.30
1
40.61
95.05
86.30
1
46.61
97.01/97.51
86.30
2
40.52/44.52/44.62 95.05/95.55
86.30
2
46.52
97.02/97.52
86.30
2
55.32
94.02
86.30
2
56.32
96.02
86.30
2
60.12
90.02
86.00/86.30
2
62.32
92.03
86.00/86.30
3
55.33
94.03
86.30
3
60.13
90.03
86.00/86.30
3
62.33
92.03
86.00/86.30
4
55.34
94.04
86.30
4
56.34
96.04
86.00/86.30
Time scales
EMC specifications
Type of test
Reference standard
86.00
86.30
Electrostatic discharge
contact discharge
EN 61000-4-2
4 kV 
n.a.
air discharge
EN 61000-4-2
8 kV
8 kV
Radio-frequency electromagnetic field (80 ÷ 1,000 MHz)
EN 61000-4-3
10 V/m
10 V/m
Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals
EN 61000-4-4
4 kV
2 kV
Surges (1.2/50 µs) on Supply terminals
common mode
EN 61000-4-5
4 kV
2 kV
differential mode
EN 61000-4-5
4 kV
1 kV
Radio-frequency common mode (0.15 ÷ 80 MHz)
EN 61000-4-6
10 V
10 V
on Supply terminals 
Radiated and conducted emission
EN 55022
class B
class B
Other data
86.00
86.30
Current absorption on signal control (B1)
mA
1
— 
Power lost to the environment
without contact current W 0.1 (12 V) - 1 (230 V) 
0.2
with rated current
See 56, 60 and 62 series relays
See 40, 44, 46, 55, 56, 60, 62 
series relays
Technical data
Combinations
Supply voltage
024 = (12...24)V AC/DC (86.30 only)
120 = (110...125)V AC (86.30 only)
240 = (12...240)V AC/DC (86.00 only)
240 = (230...240)V AC (86.30 only)
Supply version
0 = AC (50/60 Hz)/DC
8 = AC (50/60 Hz)
Series
Type
0 = Multi-function (AI, DI, SW, BE, CE, DE, EE, FE)
3 = Bi-function (AI, DI)
No. of poles
See 40, 44, 46, 55, 56, 60 and 62 series relays
Poles for chosen relay/socket combination - 
according to chart below
0
0
0
0
0
0
0
.
.
.
.
2 4 0
8 6
NOTE: Time scales and functions must be set before energising the timer.
To achieve the minimum time setting of 0.05 seconds it is necessary to use one of the functions with 
control signal
.
When setting very short times it may be necessary to take into account the operate time of the relay used.
VII-2012, www
.finder
net.com