CHIPDRIVE CLOUD 4700F 905511 数据表
产品代码
905511
CLOUD
47
X
0
F
R
EFERENCE
M
ANUAL
52
6.3.2. Escape command codes
Escape commands can be used by an application to configure CLOUD 47x0 F to function in a
mode that is not its default configured mode or to get specific information. To put the CLOUD
47x0 F back into its default mode, it either has to be unplugged and plugged again or the
application can send the same Escape command again.
mode that is not its default configured mode or to get specific information. To put the CLOUD
47x0 F back into its default mode, it either has to be unplugged and plugged again or the
application can send the same Escape command again.
The following Escape commands are supported by CLOUD 47x0 F:
6.3.3. Common for Contact and Contactless Interfaces
ESCAPE COMMAND
ESCAPE CODE
READER_SETMODE
0x01
READER_GETMODE
0x02
READER_GETIFDTYPE
0x12
READER_LED_CONTROL
0x19
READER_GETINFO_EXTENDED
0x1E
READER_LED_CONTROL_BY_FW
0xB2
READER_RDWR_USR_AREA
0xF0
READER_GENERIC_ESCAPE
FF 70 04 E6 XX
6.3.3.1. READER_SETMODE
This Escape command sets the current mode of the reader. Applications may call this function,
to set the desired mode. Typically, this call is used to switch between the ISO7816, EMV,
Memory card and NFC test mode operations. Upon power on the reader will reset to the default
ISO7816 mode.
to set the desired mode. Typically, this call is used to switch between the ISO7816, EMV,
Memory card and NFC test mode operations. Upon power on the reader will reset to the default
ISO7816 mode.
Input:
The first byte of the input buffer contains the escape code value and the second one contains
the value for the desired mode of operation. The output buffer field shall be NULL.
the value for the desired mode of operation. The output buffer field shall be NULL.
Byte0
Byte1
Escape code (0x01) Mode