CHIPDRIVE CLOUD 4700F 905511 数据表

产品代码
905511
下载
页码 98
CLOUD
 
47
X
0
 
F
 
R
EFERENCE 
M
ANUAL
  
62 
 
6.3.4.4. CNTLESS_RF_SWITCH 
 
This Escape command can be used to switch the RF field ON or OFF. 
 
Input: 
The first byte of input buffer contains the escape code.  
The second byte either sets the mode or contains a code to retrieve the setting. 
 
Output
No response is returned for set state. For Get State 1 byte response is received. 
Output buffer 
NULL  
or current state 
 
6.3.4.5. CNTLESS_SWITCH_RF_ON_OFF 
 
This Escape command is used to switch the RF field ON or OFF when a contact smart card is 
inserted into the reader. By default, the RF field is always in the ON state and when a contact 
smart card is inserted in the reader, the RF field is turned OFF.  
 
Input: 
The first byte of input buffer contains the escape code. 
The second byte either sets the mode or contains a code to retrieve the setting. 
 
After the RF is turned off, to turn the RF ON again, card connect has to be done in direct mode. 
Byte0 
Byte1 
Output 
Value  Description 
Byte0 
Escape code(0x96) 
0x00 
Switch RF Field OFF 
 
No Output 
0x01 
Switch RF Field ON  
No Output 
0xFF 
Get current field state  
0 – RF field is ON 
1 – RF field is OFF 
Byte0 
Byte1 
Output 
Value 
Description 
Byte 0 
Escape 
code(0x9C) 
0x00 
Switch RF Field OFF when contact 
card is present in the reader  
No Output 
0x01 
Leave RF Field ON when contact 
card is present in the reader  
No Output 
0xFF 
Get current field state  
0x00 -  RF is OFF when contact 
card is present in the reader 
0x01 -  RF is ON when contact 
card is present in the reader