CHIPDRIVE CLOUD 4700F 905511 数据表

产品代码
905511
下载
页码 98
CLOUD
 
47
X
0
 
F
 
R
EFERENCE 
M
ANUAL
  
84 
 
6.3.5.8. CONTACT_GET_SET_CLK_FREQUENCY 
 
This Escape command is used to instruct the reader to change the clock for the smart card or 
to get the current Clock divisor used. Once set, the change in frequency will take effect 
immediately. Default divisor value is 10, that is 4.8MHz. 
Input: 
The first byte of the input buffer contains the Escape code; the next byte contains the clock 
divisor value to set the clock frequency or 0xFF to get the clock frequency. 
 
Output: 
Set clock frequency: None 
Get clock frequency: One byte value indicating the current Clock divisor. 
Output buffer 
NULL or 
current divisor 
 
 
Clock Divisor values: 
DIVISOR VALUE  SCCLK Frequency 
12 
4 MHz 
10 
4.8 MHz 
6 MHz 
6.8 MHz 
8 MHz 
9.6 MHz 
12 MHz 
16 MHz 
 
Byte0 
Byte1 
Value 
Description 
Escape code(0x1F)  Clock divisor  The value to be Set  in the smartcard CLK divisor register 
0xFF 
Get current Clock divisor value