does not perform its function.
If the test is completed without errors, the actuator 
transmits a wireless telegram containing its status in-
formation. To prevent all actuators from transmitting at 
the same time when power is recovered (after a mains 
power failure or a disconnection, for example), there 
is a random delay before the actuator transmits. Dur-
ing this time, the device LED flashes (as in teach-in 
mode). If the delay is very short, this flashing may be 
almost imperceptible.
11  Maintenance and cleaning
The product does not require any maintenance.  
Enlist the help of an expert to carry out any repairs.
The device features an internal miniature fuse (fuse 
holder 
C) to protect the electronics against current 
overload. If the device is overloaded and the fuse 
blows, it can be replaced. 
Check the connected load for faults before putting the 
device back into operation.
Replacement fuses must always be of the same type 
(miniature fuse 20 mm, 1.6 A slow-blowing). 
The device must be disconnected from the power sup-
ply before replacing the fuse (to do this, simply unplug 
it from the socket).