Fujitsu PRIMERGY TX150 S6 VFY:T1506SF040NL 产品宣传页
产品代码
VFY:T1506SF040NL
Data sheet
Issue: February 25, 2008
PRIMERGY TX150 S6
Page 2 / 2
All rights reserved, including intellectual property rights. Technical data subject to modifications and
delivery subject to availability. Any liability that the data and illustrations are complete, actual or
correct is excluded.
Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which
by third parties for their own purposes may infringe the rights of such owner.
For further information see http://www.fujitsu-siemens.com/terms_of_use.html
Copyright © Fujitsu Siemens Computers 03/2008
delivery subject to availability. Any liability that the data and illustrations are complete, actual or
correct is excluded.
Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which
by third parties for their own purposes may infringe the rights of such owner.
For further information see http://www.fujitsu-siemens.com/terms_of_use.html
Copyright © Fujitsu Siemens Computers 03/2008
Published by
Fujitsu Siemens Computers
http://www.fujitsu-siemens.com/
Company stamp
Type
Mono Socket Tower Server
System board
D2559
Chip set
Intel® 3210
Processors
Intel® Celeron® /
Intel® Pentium DC / Core2 Duo /
Intel® Xeon® UP (Dual- or Quad-Core)
Intel® Pentium DC / Core2 Duo /
Intel® Xeon® UP (Dual- or Quad-Core)
Type /
Frequencies (GHz)
Frequencies (GHz)
440 (2.0) 35W / E2140 (1.60) / E4500 (2.20) /
3065 (2.33) / E3110 (3.00) DC all 65W /
X3210 (2.13); X3220 (2.40) GHz QC 95W /
X3350 (2.66); X3360 (2.83) all 95W QC
3065 (2.33) / E3110 (3.00) DC all 65W /
X3210 (2.13); X3220 (2.40) GHz QC 95W /
X3350 (2.66); X3360 (2.83) all 95W QC
Front-Side-Bus
800 / 1066 (X32xx) / 1333 MHz DC Xeon UP
und X33xx
und X33xx
Second-Level-
Cache
Cache
512 KB / 1 MB / 2 MB / 4 MB / 6 MB DC Xeon
/ 2x 4 (32xx) / 2x 6 MB (33xx), ECC
/ 2x 4 (32xx) / 2x 6 MB (33xx), ECC
Memory
512 MByte up to max. 8 GByte
ECC unbuffered DDR2 800 SDRAM; 2 banks with 2 slots each; (512
Mbyte, 1, 2 Gbyte each)
Mix and match possible; with dual channel operation better
performance (2 modules with equal capacity necessary). Single
channel (1 module) configuration possible.
Flash-EPROM
Mbyte, 1, 2 Gbyte each)
Mix and match possible; with dual channel operation better
performance (2 modules with equal capacity necessary). Single
channel (1 module) configuration possible.
Flash-EPROM
Local BIOS update with floppy disk; Remote BIOS-Update via LAN
with Global Flash and service partition
Interfaces
with Global Flash and service partition
Interfaces
Serial
1 x serial RS-232-C (9-pin) usable for
iRMC or system or shared
1 x serial RS-232-C (9-pin) (optional)
iRMC or system or shared
1 x serial RS-232-C (9-pin) (optional)
Centronics (parallel)
1 x 25-pin, EPP/ECP compatible (opt.)
Keyboard, Mouse
2 x PS/2
USB 2.0
1 x front, 4 x back
2 x internal for backup drives, 1x USB stick
2 x internal for backup drives, 1x USB stick
Graphics
1 x VGA (15-pin)
LAN
1 x LAN RJ45, 1 x Service LAN 10/100
Onboard controller **
SATA variant
(Intel® ICH9R)
(Intel® ICH9R)
6 port SATA for 4 internal HDD`s with
RAID 0, 1, 10 for Windows and Linux,
RAID 5 iButton key optional, 2 ports for
accessible drives also in SAS variant
RAID 0, 1, 10 for Windows and Linux,
RAID 5 iButton key optional, 2 ports for
accessible drives also in SAS variant
SAS configuration
in PCIe slot either
LSI 1068e
or LSI 1078
in PCIe slot either
LSI 1068e
or LSI 1078
8 port SAS for internal HDD´s and internal
backup devices with
RAID 0, 1 (Integrated Mirroring Enhanced
also for odd numbered HD´s for Windows
and Linux)
with RAID 0, 1, 10, 5, 50, 6; 60 (256 or 512
MB RAID Cache and opt. BBU)
backup devices with
RAID 0, 1 (Integrated Mirroring Enhanced
also for odd numbered HD´s for Windows
and Linux)
with RAID 0, 1, 10, 5, 50, 6; 60 (256 or 512
MB RAID Cache and opt. BBU)
LAN (Broadcom
BCM5755)
BCM5755)
1x Ethernet 10/100/1000 Mbit/s (PXE-Boot
via LAN from PXE server), iSCSI Boot
(also diskless) via onboard LAN
via LAN from PXE server), iSCSI Boot
(also diskless) via onboard LAN
Server management
Integrated Remote Management Controller
(iRMC S2) incl. graphics controller, IPMI
2.0
(iRMC S2) incl. graphics controller, IPMI
2.0
TPM (optional)
Infineon / 1.2
Hard disk drives
73, 146, 300 Gbyte 3.5-inch SAS or 36, 73,
146 Gbyte 2.5-inch SAS or 160, 250, 500,
750 Gbyte 3.5-inch SATA
No mix SAS / SATA, no later conversion
from 3,5 to 2,5-inch possible
146 Gbyte 2.5-inch SAS or 160, 250, 500,
750 Gbyte 3.5-inch SATA
No mix SAS / SATA, no later conversion
from 3,5 to 2,5-inch possible
1 Gbyte equals one billion bytes when referring to hard disk drive capacity; accessible
capacity may vary.
capacity may vary.
I/O Slots:
2 x PCI-Express x8, short
1 x PCI-Express x4, short
3 x PCI 32-bit / 33MHz, 2x long (5V);
(in SAS configuration 1x PCIe occupied with modular RAID)
Drive bays
2 x PCI-Express x8, short
1 x PCI-Express x4, short
3 x PCI 32-bit / 33MHz, 2x long (5V);
(in SAS configuration 1x PCIe occupied with modular RAID)
Drive bays
for hard disks
4x 3.5-Zoll, for Hot-plug SAS/SATA or
8x 2.5-Zoll, for Hot-plug SAS
(in slide-in chassis)
8x 2.5-Zoll, for Hot-plug SAS
(in slide-in chassis)
for optional
hard disks
hard disks
2x 3.5-inch HDD box SAS only in SAS
configuration (occupies 2x 5.25-inch bay)
configuration (occupies 2x 5.25-inch bay)
for accessible
drives
drives
3x 5.25/1.6-inch, (all possible options
described in relevant system configurator)
1x 3,5/1-inch, for FDD (optional)
described in relevant system configurator)
1x 3,5/1-inch, for FDD (optional)
Electrical values
1x standard or 2x optional redundant hot-plug power supplies
Output power
Output power
350 W / 1 + 1 x 400 W each
Rated voltage range
100 - 240 V
Rated frequency
50-60 Hz
Max. rated current
100 V - 240 V / 6 A – 3 A
Rated current in
basic configuration
basic configuration
100 V - 240 V / 1.9 - 0.8 A
Active power (min – max)
64 - 232 W
Apparent power (min – max)
86 - 263VA
Heat emission (min – max)
230 - 835 kJ/h (218 - 792 btu/h
Temperature/Noise/Dimensions/Weight
Ambient temperature
10°C - 35°C (DIN IEC 721-3-3) class
3K2; ETSI 300 019-2-3 Class 3.1
3K2; ETSI 300 019-2-3 Class 3.1
Declared noise in
according with ISO 9296
according with ISO 9296
Idle* / operating* (*ISO 7779)
ETSI 300 753 Class 3.1
ETSI 300 753 Class 3.1
Sound pressure L
pAm
26 db(A) /35 db(A)
Sound power L
WAd
4.4 B / 5.3 B (1 BEL = 10 db)
Dimension
of floor-stand (HxWxD)
of floor-stand (HxWxD)
444 x 205 x 605 mm,
incl. all plastics
incl. all plastics
Rack (HxWxD)
221 x 482 x 607 mm;
Rack mounting depth mm; 5U
Rack mounting depth mm; 5U
Weight
Up to 28 kg
Compliance with Norms and Standards
Product safety
Product safety
Global
IEC 60950
Europe
EN 60950
USA
UL 60950 3rd. Ed.
Canada
CAN/CSA-C22.2 No. 60950 3rd. Ed.
Electromagnetic compatibility
This product and the released accessories, are in compliance with
emission class A. In certain cases measures have to be taken to
reduce the electro magnetic influence to other equipment.
Europe
This product and the released accessories, are in compliance with
emission class A. In certain cases measures have to be taken to
reduce the electro magnetic influence to other equipment.
Europe
EN 55 022 class A, EN 55024,
EN61000-3-2 / -3, ETSI EN300386
EN61000-3-2 / -3, ETSI EN300386
USA / Canada
FCC class A
Declaration of conformity
Europe (CE)
89/336/EEC;
73/23 EEC
73/23 EEC
North America
FCC class A
Approvals
Product safety
Global
CB
Europe
CE
USA / Canada
CSA
US
/ CSA
C
There is general compliance with the safety requirements of all
European countries and North America. National approvals required
in order to satisfy statutory regulations or for other reasons, can be
applied for on request.
European countries and North America. National approvals required
in order to satisfy statutory regulations or for other reasons, can be
applied for on request.
Supported operating systems
See actual release status
See actual release status
operating systems
: e.g. Windows 2003;
Novell SUSE Linux Enterprise Server , Red Hat Enterprise Linux;
VMware Infrastructure (Support of Debian, Ubuntu, Mandriva Linux
and other Linux derivatives
VMware Infrastructure (Support of Debian, Ubuntu, Mandriva Linux
and other Linux derivatives
on demand
)
** For supported controllers (onboard and PCI cards for SATA, SAS,
RAID, LAN, WAN, etc.), please refer to the corresponding system
configurator.
Server Management (see separate data sheets)
RAID, LAN, WAN, etc.), please refer to the corresponding system
configurator.
Server Management (see separate data sheets)
Standard
PRIMERGY ServerView Suite;
PDA, ASR&R
PDA, ASR&R
Optional (excerpt)
iRMC S2 Advanced Pack ServerView
Local Service Panel (LSP)
Local Service Panel (LSP)