• Setting the target number (remote TA)
at&z1=
XXX
• Setting the alarm text
at*v
common text for both alarms (collective message)
at*v1
individual text for alarm 1
at*v2
individual text for alarm 2
-> NEW ALARMTEXT:
Enter the new text: max. 160 characters for collective mes-
sage if the individual texts are empty, otherwise 120 char-
acters for collective message and 40 characters for each in-
dividual text.
acters for collective message and 40 characters for each in-
dividual text.
• Setting the alarm function (optional)
at*y2
Connection will be terminated by deactivating the alarm
input (only for alarm input 1)
input (only for alarm input 1)
• Storing the settings
at&w
Configuration of the remote ISDN TA
• Setting the MSN (own call number)
at**msn=
xx
xxx stands for the call number
• Setting the baud rate
at%b
x
x stands for the selection of the respective baud rate, see
chapter: Overview about the most important basic com-
mands
chapter: Overview about the most important basic com-
mands
• Automatic call acceptance
ats0=1
Call acceptance after first ring
• Storing the settings
at&w