2.1.2 Digital Output
switched voltage is VIN; high side switch
max. Output 400mA
short circuit protected
ESD protected
under full control of embedded application
The following command has to be used to initialise and to set the digital output:
AT#GPIO=6,1,1
output switched on
AT#GPIO=6,0,1
output switched off
2.2 Mini USB Connector
There exist two different variants of the terminal module, both in the same housing,
and both equipped with the USB-type connector:
HT910 Standard
The HT910-Standard uses the USB connector for data communication but
requires the use of the power connector to power the device.
HT910 USB Powered
The HT910-USB powered variant is be powered directly from the USB
connector via a standard 5V USB interface.  The RJ11 Power connector is
assembled but not connected to anything.
You will find the version of your HT910 on the label on the bottom of the device.