Cep Terminals 6201 GSM Remote Switch Control Module 6201 数据表

产品代码
6201
下载
页码 32
CEP AG 
 
Revision 1.4 
 
_________________________________________________________________________________ 
__________________________________________________________________________________________   
 
 
 
Page 11 of 32 
3  Operation 
3.1  Switching ON the modem 
 
There are two ways to switch on the modem, once power is applied: 
 
• assert TO_IN to high level for > 1s 
• activate the RS232 control line DTR 
 
The modem is fully operational after 4 seconds. Logging onto a network may take 
longer than this and is outside the control of the modem. The modem can be 
configured to start up at the time power is applied by permanently tying power 
connector signals TO_IN (pin 4) and VCC (pin 1) together. In this case DTR must be 
used to switch the modem on again after it has been switched off or reset, while 
power is still applied. 
 
Note: DTR must be cycled from low to high. 
 
Note: 
The TO_IN signal requires a positive “edge” (a sharp” signal transition from low 
to  high)  to  turn  the  modem  on.  This  transition  should  be  a  rising  signal  from  0V 
(GND) to VCC, or at least a large fraction of that voltage range, and must be applied 
at  the  same  time  as  VCC  or  after  it.  Very  slow  transitions  (significantly  slower  than 
many milliseconds) or very small transitions (e.g. only few volts instead of 0V to VCC) 
will not turn on the module (since they ar
e not considered to be a “positive edge”). 
 
Although this will not be an issue in almost all typical applications of the modem, 
please consider following points: 
  Large capacitors in your power supply which will lead to slow leading and 
falling edges (issue does not apply with modern stabilized switching regulator 
power-adaptors) AND TO_IN tied in parallel to VCC (instead of separate 
dedicated digital signal) 
  Slow analogue signals used to assert TO_IN 
  TO_IN signal not before VCC 
 
All 3 cases above might prevent the modem from recognizing the power-up signal 
this is no failure of the modem itself, the same would apply to almost any electronic 
device that provides a separate “power-on” or “reset” signal. 
 
If you are doubt, please 
  Use the mains power adapter that is provided by your distributor and is know 
to work properly with your modem 
  Make sure that your signal and system design is according to the above 
  Consult our support team that will be more than happy to assist you.