Texas Instruments TPS53219EVM-690 Wide-Input Voltage Eco-mode™, Single, Synchronous, Step-Down Controller TPS53219EVM-69 TPS53219EVM-690 数据表

产品代码
TPS53219EVM-690
下载
页码 21
T
I
NSTRUMENTS
EXAS
V1
A1
DC
Source
Vin
-
Load
+
V2
FAN
+
-
Configurations
www.ti.com
5.2
Recommended Test Setup
Figure 3. TPS53219EVM-690 Recommended Test Set Up
is the recommended test setup to evaluate the TPS53219EVM-690. Working at an ESD
workstation, make sure that any wrist straps, bootstraps or mats are connected referencing the user to
earth ground before power is applied to the EVM.
Input Connections:
1. Prior to connecting the dc input source Vin, it is advisable to limit the source current from Vin to 10 A
maximum. Ensure that Vin is initially set to 0 V and connected as shown in
.
2. Connect a voltmeter V1 at TP7 (Vin) and TP8 (GND) to measure the input voltage.
3. Connect a current meter A1 to measure the input current.
Output Connections:
1. Connect Load to J5, and set Load to constant resistance mode to sink 0 Adc before Vin is applied.
2. Connect a voltmeter V2 at TP14 (Vout) and TP15 (GND) to measure the output voltage.
Other Connections:
Place a fan as shown in
and turn on, ensuring that air is flowing across the EVM.
6
Configurations
All jumper selections must be made prior to applying power to the EVM. Users can configure this EVM per
the following configurations.
6.1
Switching Frequency Selection
The switching frequency can be set by J1.
Default setting: 300kHz
6
Using the TPS53219EVM-690 Wide-Input Voltage, Eco-mode™, Single,
SLVU431 – January 2011
Synchronous, Step-Down Controller
© 2011, Texas Instruments Incorporated