Texas Instruments CC2650DK 用户手册
![Texas Instruments](https://files.manualsbrain.com/attachments/b46f99d826b2b0e0e5f558c5fb6483942eb9216b/common/fit/150/50/c15ea36eb1fb1cce99a3b94668675bfc78ce832d8d727d9a7bb51a125510/brand_logo.gif)
PRCM Registers
6.2.1.49 PDCTL1VIMS Register (Offset = 18Ch) [reset = X]
PDCTL1VIMS is shown in
and described in
.
VIMS Power Domain Control
Figure 6-55. PDCTL1VIMS Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESERVED
R-X
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESERVED
ON
R-X
R/W-
1h
Table 6-57. PDCTL1VIMS Register Field Descriptions
Bit
Field
Type
Reset
Description
31-1
RESERVED
R
X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
other value than the reset value may result in undefined behavior.
0
ON
R/W
1h
This is an alias for PDCTL1.VIMS_MODE
478
Power, Reset, and Clock Management
SWCU117A – February 2015 – Revised March 2015