Texas Instruments LDC1000EVM - Evaluation Module for Inductance to Digital Converter with Sample PCB Coil LDC1000EVM LDC1000EVM 用户手册

产品代码
LDC1000EVM
下载
页码 5
3
LDC1000EVM Quick Start Guide
Texas Instruments   2013
 
  Keep target at desired minimum sensing distance. Reconfigure  
    Rp_MIN to a higher value such that “Proximity Data” is close  
    to 32768 (2
15
)
 
  Keep target at desired maximum sensing distance. Reduce Rp_MAX 
    sequentially until “Proximity Data” becomes 0. Set final value of 
    Rp_MAX to last working value with “Proximity Data” greater than 0.
Waveform on CFB with 100 pF
Waveform on CFB with 20 pF
Amplitude: 0.2 V
PP
Amplitude: 1 V
PP
Note: Make sure to set time base of the oscilloscope to 1/5 of the oscillation period, 
to observe appropriate amplitude
5. Verify waveform on CFB pin as in image 
(continued)
To maximize the performance of your custom sensor, follow the additional instructions in 
the LDC1000 datasheet to optimize your R
P
 settings.
4a
4d
4b
4c
6. Press START to begin data capture
7. Move conductive target near to/far from coil, and observe  
  LDC response (as in Fig. 1)
 
  If using a spring as sensor – compress, expand and twist to see  
    changes in response
Fig. 3  Example setting
Fig. 4  Expected waveforms