SLUSB97 – OCTOBER 2012
Termination when REG05[6] = 1
Usually the STAT bit indicates charging complete when the charging current falls below termination threshold.
Write REG05[6]=1 to enable an early “charge done” indication on STAT pin. The STAT pin goes high when the
charge current reduces below 800mA. The charging cycle is still on-going until the current falls below the
termination threshold.
Charging Safety Timer
The bq24195L, bq24195 has safety timer to prevent extended charging cycle due to abnormal battery conditions.
In default mode, the device keeps charging the battery with 5-hour fast charging safety timer regardless of
REG05[2:1] default value. At the end of the 5 hours, the EN_HIZ (REG00[7]) is set to signal the buck converter
stops and the system load is supplied by the battery. The EN_HIZ bit can be cleared to restart the buck
converter.
In host mode, the device keeps charging the battery until the fast charging safety timer expired. The duration of
safety timer can be set by the REG05[2:1] bits (default = 8 hours). At the end of safety timer, the EN_HIZ
(REG00[7]) is cleared to signal the buck converter continues to operation to supply system load.
The safety timer is 1 hour when the battery is below BATLOWV threshold. The user can program fast charge
safety timer through I
2
C (REG05[2:1]). When safety timer expires, the fault register REG09[5:4] goes 11 and an
INT is asserted to the host. The safety timer feature can be disabled via I2C (REG05[3]).
The following actions restart the safety timer:
At the beginning of a new charging cycle
Toggle the CE pin HIGH to LOW to HIGH (charge enable)
Write REG01[5:4] from 00 to 01 (charge enable)
Write REG05[3] from 0 to 1 (safety timer enable)
Write REG01[7] to 1 (software reset)
During input voltage/current regulation or thermal regulation, the safety timer counts at half clock rate since the
actual charge current is likely to be below the register setting. For example, if the charger is in input current
regulation (IINDPM) throughout the whole charging cycle, and the safety time is set to 5 hours, the safety timer
will expire in 10 hours. This feature can be disabled by writing 0 to REG07[6].
USB Timer when Charging from USB100mA Source
The total charging time in default mode from USB100mA source is limited by a 45-min max timer. At the end of
the timer, the device stops the converter and goes to HIZ.
Host Mode and Default Mode
The bq24195L, bq24195 is a host controlled device, but it can operate in default mode without host
management. In default mode, bq24195L, bq24195 can be used as an autonomous charger with no host or with
host in sleep.
When the charger is in default mode, REG09[7] is HIGH. When the charger is in host mode, REG09[7] is LOW.
After power-on-reset, the device starts in watchdog timer expiration state, or default mode. All the registers are in
the default settings.
Any write command to bq24195L, bq24195 transitions the device from default mode to host mode. All the device
parameters can be programmed by the host. To keep the device in host mode, the host has to reset the
watchdog timer by writing 1 to REG01[6] before the watchdog timer expires (REG05[5:4]), or disable watchdog
timer by setting REG05[5:4]=11.