FIGURE 3-1:
Main Screen with Active Results Frame.
The “Instantaneous Parameters” field contains the recent meter output parameters,
such as Active Power, Reactive Power, Apparent Power, RMS Current, RMS Voltage
and Frequency. The registers in this frame are continuously collected and refreshed on
the PC side periodically.
Table 3-1 shows examples of the meter readings.
TABLE 3-1:
REGISTERS READINGS OF THE METER
Meter Reading
Register
Example
Active Power
POWER_ACT
101.44W
Reactive Power
POWER_REACT
17.2371 VAR
Apparent Power
POWER_APP
102.894 VA
RMS Current Phase A
I_RMS
0.45A
RMS Voltage Phase A
V_RMS
220.6V
Frequency
FREQUENCY
50 Hz