Microchip Technology MA330012 数据表

下载
页码 370
dsPIC33F
DS70165E-page 348
Preliminary
©
 2007 Microchip Technology Inc.
TABLE 26-41: ADC CONVERSION (10-BIT MODE) TIMING REQUIREMENTS 
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
-40°C
 
≤ 
T
A
 
≤ 
+85°C 
Param 
No.
Symbol
Characteristic
Min.
Typ
(1)
Max.
Units
Conditions
Clock Parameters
AD50
T
AD
ADC Clock Period
70
ns
T
CY
 = 70ns, ADxCON3 
in default state
AD51
t
RC
ADC Internal RC Oscillator Period
250
ns
Conversion Rate
AD55
t
CONV
Conversion Time
12 T
AD
AD56
F
CNV
Throughput Rate
1.1
Msps
AD57
T
SAMP
Sample Time
1 T
AD
Timing Parameters
AD60
t
PCS
Conversion Start from Sample
Trigger
(3)
1.0  T
AD
Auto-Convert Trigger 
(SSRC<2:0> = 
111
) not 
selected
AD61
t
PSS
Sample Start from Setting
Sample (SAMP) bit
0.5 T
AD
1.5 T
AD
AD62
t
CSS
Conversion Completion to
Sample Start (ASAM = 
1
)
(3)
0.5  T
AD
AD63
t
DPU
Time to Stabilize Analog Stage 
from ADC Off to ADC On
(3)
20
μ
s
Note 1:
These parameters are characterized but not tested in manufacturing.
2:
Because the sample caps will eventually lose charge, clock rates below 10 kHz can affect linearity 
performance, especially at elevated temperatures.
3: