Input Terminals 
 
Background 
There are 3 terminals for the 300A, 30A and 
3A/300mA/30mA ranges, respectively.  
The 300A range uses the rear panel terminals 
and uses M8 crimped terminal cables. 
The 30A range uses the 30A terminal and uses 
M4 sized crimped terminal cables or banana 
plugs. 
The 3A input terminal uses standard banana 
plugs (GW Instek part number GTL-105A). The 
3A terminal supports 3A, 30mA and 300mA 
ranges. 
WARNING 
Ensure any current or voltage sources are disabled 
before connecting any cables to the PCS-1000.   
Steps 
1.  Turn the power switch off. 
POWER
 
 
2.  Connect the PCS-1000 in series 
with the load and source. The 
current monitor output can be 
used in conjunction with a voltage 
meter. 
 WARNING:  
Do not short the positive or negative 3A, 30A and 