Rigol DM3058 Digital-Multimeter, DMM, DM3058 数据表

产品代码
DM3058
下载
页码 23
RIGOL 
                                        
Quick Guide for DM3058/DM3058E 
E
N
G
L
IS
H
 
 
Power Selection 
The Multimeter operates on multiple power distribution standards 
and must be set up to operate on the line voltage that will power it. 
If the selected line  voltage does not match the power that the 
Multimeter will be plugged into, the Multimeter’s linevoltage setting 
must be changed. The power selector is under the power switch on 
the rear panel.
   
To change the fuse 
The fuse located in the rear panel of the Multimeter, it is a kind of 
fast-melt, no-burst, F300mA, 5×20mm one.   
 
To Change the Fuse 
Operation steps: 
1
  Disconnect the power. Use the Straight Screwdriver  to press 
down the block (as the dashed line point out), and then pull out 
the seat of the fuse. 
2  Choose the correct voltage shelves location in the voltage 
selected switches. 
3  Enclose the seat of the fuse to the slot after placed the fuse. 
 
 
WARNING:  To avoid electric shock or fire, do not use 
makeshift fuses or short-circuit the fuse holder.