Freescale Semiconductor TWR-K70F120M High-Performance MCUs with Graphics LCD, Connectivity and Security TWR-K70F120M-KIT TWR-K70F120M-KIT 用户手册

产品代码
TWR-K70F120M-KIT
下载
页码 24
 
 
 
 
 
TWR-K70F120M Tower Module User's Manual 
Page 14 of 24 
 
TWR-SER 
J2 
3-4 
TWR-SER 
J3 
2-3 
TWR-SER 
J12 
9-10 
2.14 USB 
The K70FN1M0 features two different USB modules--a USB full-speed/low-speed OTG/Host/Device 
controller with built-in transceiver and a high-speed OTG/Host/Device controller that requires a 
external ULPI PHY.  
 
2.14.1 FS/LS USB 
The TWR-K70F120M routes the USB D+ and D- signals from the K70 MCU to the Primary Connector, 
allowing the connection to external USB connectors or additional circuitry on a Tower peripheral 
module. 
 
The TWR-SER module included as part of the TWR-K70F120M-KIT provides a USB OTG/Host/Device 
interface with a mini-AB USB connector.  There are many configuration options that can be selected to 
evaluate different USB modes of operation.  By default, the TWR-SER is configured for USB Device 
operation. Please refer to the documentation included with the TWR-SER for more information on the 
configuration options. 
2.14.2 HS USB 
The TWR-K70F120M routes the ULPI interface signals for the high-speed USB module to the Secondary 
Connector allowing the connection to an external ULPI PHY or additional circuitry on a Tower 
peripheral module. 
 
The TWR-SER2 module includes a ULPI PHY that can be used with the TWR-K70F120M in order to 
evaluate the high-speed USB functionality. The TWR-SER2 is not included as part of the TWR-
K70F120M-KIT, but the boards can be ordered individually from Freescale. 
2.15 Secure Digital Card Slot 
A Micro-Secure Digital (SD) card slot is available on the TWR-K70F120M connected to the SD Host 
Controller (SDHC) signals of the K70 MCU.  This slot will accept micro-SD memory cards. Refer to Table 
6 “I/O Connectors and Pin Usage Table”
 for the SDHC signal connection details. 
2.16 External Bus Interface – FlexBus 
The K70 device features a multi-function external bus interface called the FlexBus interface controller 
capable of interfacing to slave-only devices. The FlexBus interface is not used directly on the TWR-
K70F120M.  Instead, a subset of the FlexBus is connected to the Primary Connector so that the external 
bus can access devices on Tower peripheral modules. Refer to Table 7 “TWR-K70F120M Primary 
Connector Pinout”
 and sheet 8 of the TWR-K70F120M schematics for more details.