15
 
Differential input CAN signals, for both CAN channels, are terminated with 120 ohms.  Option 
headers, JP13 and JP15 allow the user to optionally disconnect signal termination.   Avalanche 
diodes protect the CAN PHY from voltage surges on the input differential signal lines.   Figure 
13 
below shows the CAN connector pin-out. 
Figure 13: CAN_PORT 
J7   
 
 
C
A
NL_
0
 
CANH
_
0
 
CANL
_
1
 
CANH
_
1
 
 
 
 
 
Front View 
– 
Looking into 
Connector
 
 
NOTE:  
CAN Port Connector 
– Molex 39-30-3045 
 
Mates with; Housing 
– Molex 39-01-4040, Pin – Molex 39-00-0036 
CAN Termination Enable 
CAN bus termination of 120 ohm with virtual ground is applied to the differential CAN signals 
on both channels.  The SPLIT output from each PHY is connected to the virtual ground 
providing common-mode stabilization.  The differential CAN bus signal termination may be 
removed using option header JP13 or JP15.  To prevent signal corruption, both option jumpers 
must be installed or both option jumpers must be removed.  The CAN bus should not be 
operated with only 1 signal termination applied.   
  
 
NOTE: 
To prevent signal corruption both shunts should be either ON or OFF 
Figure 14: CAN Termination Enable 
 
 
Connects CANL termination  
 
 
Connects CANH termination 
JP13 
 
 
NOTE:  JP13 applies termination to CAN0 while JP15 applies termination to CAN1.  JP15 is 
similar to JP13.