Motor Controller (MC10B8CV1)
MC9S12XHY-Family Reference Manual, Rev. 1.04
Freescale Semiconductor
675
20.3.2.3
Motor Controller Period Register
The period register defines PER, the number of motor controller timer counter clocks a PWM period lasts.
The motor controller timer counter is clocked with the frequency f
TC
. If dither mode is enabled (DITH = 1,
refer to
), P0 is ignored and reads as a 0. In this case
PER = 2 * D[10:1].
For example, programming MCPER to 0x0022 (PER = 34 decimal) will result in 34 counts for each
complete PWM period. Setting MCPER to 0 will shut off all PWM channels as if MCAM[1:0] is set to 0
in all channel control registers after the next period timer counter overflow. In this case, the motor
controller releases all pins.
NOTE
Programming MCPER to 0x0001 and setting the DITH bit will be managed
as if MCPER is programmed to 0x0000. All PWM channels will be shut off
after the next period timer counter overflow.
Offset Module Base + 0x0002, 0x0003
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
0
0
0
0
0
P10
P9
P8
P7
P6
P5
P4
P3
P2
P1
P0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 20-5. Motor Controller Period Register (MCPER) with DITH = 0
Offset Module Base + 0x0002, 0x0003
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
0
0
0
0
0
P10
P9
P8
P7
P6
P5
P4
P3
P2
P1
0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 20-6. Motor Controller Period Register (MCPER) with DITH = 1